Main Scan Magnification Adjustment; Image Processing - Konica Minolta bizhub C35 Service Manual

Hide thumbs Also See for bizhub C35:
Table of Contents

Advertisement

DRAFT
8. WRITE SECTION
8.2.5

Main scan magnification adjustment

• Magnification of the main scan direction is adjusted.
• The main body is mounted with only one IDC sensor and therefore unable to make the
main scan magnification adjustment or calculate the skew amount automatically.
The main scan magnification adjustment is therefore manually made using the menu on
the control panel.
• The adjustment is necessary when the adjustment value is cleared, such as when the
PH unit or the EEPROM on the printer control board is replaced with a new one.
8.2.6

Image processing

• The following image stabilization functions are available as they relate to the write sec-
tion. For more details, see "Image stabilization control".
• Laser light intensity correction control
• Color registration correction control (main scan/sub-scan)
• Gamma correction