On-Board Points; Terminals 11 To 22 Description; Point Sensor Loops; Point Parameters - Bosch D9412GV2 Operation And Installation Manual

Hide thumbs Also See for D9412GV2:
Table of Contents

Advertisement

.

8.0 On-Board Points

8.1

Terminals 11 to 22 Description

The control panel provides eight on-board points.
Each point functions independently and does not
interfere with the operation of the others. The control
panel monitors the sensor loops for normal, shorted,
or open conditions between an input terminal (11, 13,
14, 16, 17, 19, 20, or 22) and any of the point
common terminals (12, 15, 18, and 21). The
programming for the point determines how the control
panel responds to those conditions. Refer to the
D9412GV2/D7412GV2 Program Entry Guide (P/N:
F01U003636) for point programming options. The
control panel also monitors the sensor loops for
ground fault conditions if S4 is latched (ground fault
detect enabled).
8.2

Point Sensor Loops

Not for use in Fire Applications
When wiring the on-board points (Figure 14), install
a 1 kΩ resistor at the far end of the sensor loop to
provide a reference for supervision. Dry-contact
sensing devices can be connected in series
(normally-closed) or in parallel (normally-open) to any
of these loops.

Figure 14: On-board Point Sensor Loop Wiring

2
3
2
3
2
1 - 100 Ω maximum
2 - Point input terminal
3 - Common
4 - Normally-closed contacts (NC)
5 - Normally-open contacts (NO)
6-
Combination: Normally-open contacts and
normally-closed contacts (NO/NC)
Bosch Security Systems, Inc. | 7/09 | F01U003641-04
D9412GV2/D7412GV2 | Operation and Installation Guide | 8.0
1
4
5
6
The number of normally-open and normally-closed
detection devices each sensor loop can supervise is
limited only by the resistance on the loop. The total
resistance for the wire length and contacts, minus the
end-of-line (EOL) resistor, must not exceed 100 Ω.
8.3

Point Parameters

The condition of on-board Points 1 to 8 is determined
by measuring the voltage across the point input
terminal and one of the common terminals. The
sensor loops must be connected and the 1 kΩ EOL
resistor in place.
Table 10:

Point Parameters

Loop
Voltage Range
Open
Greater than 3.7 VDC, but less than 5.0
VDC.
Normal
Greater than 2.0 VDC, but less than 3.0
VDC.
Shorted
Greater than 0.0 VDC, but less than 1.3
VDC.
7 - P105F (Package of 8 EOL resistors) or
P105BL (Package of 8 UL Listed EOL
resistors) (P/N: 15093130-004)
8 - Brown
9 - Black
10 - Red
On-Board Points
7
1 kΩ
8
10
10
9
9