D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points

Figure 24: D8128D OctoPOPIT Sensor Loops

COM IN OUT+12V P1 COM P2
2
1 - D8128D OctoPOPIT
2 - To control panel
3 - To additional OctoPOPIT sensor loops
4 - OctoPOPIT sensor loops
5 - 1 kΩ EOL resistor (P/N: P105BL, package of
eight)
9.5

Testing Off-Board Points

Use the Service Walk Test to test off-board points.
Refer to the D9412GV2/D7412GV2/D7212GV2
Installation and Troubleshooting Quick Reference
Guide (P/N: F01U003638) for instructions. Test to
ensure that all off-board points operate properly.
Walk Test and Service Walk Test Do Not Show
Extra Points: If the point assignment switches on a
POPIT or OctoPOPIT are set incorrectly, missing and
extra points can occur. If the same point number is
assigned to two or more POPITs or OctoPOPITs,
none of the points with that number test correctly.
Refer to Section 9.1 Point (Zonex) Bus: D9412GV2
Terminals and D7412GV2 Terminals on page 39.