Electrical - Worcester GREENSTAR 24i Junior Installation Instructions Manual

Wall hung rsf gas-fired condensing combination boiler
Table of Contents

Advertisement

INSTALLATION
4.7

ELECTRICAL

CAUTION: ISOLATE THE MAINS
ELECTRICITY SUPPLY BEFORE STARTING
ANY WORK AND OBSERVE ALL RELEVANT
SAFETY PRECAUTIONS.
The boiler is pre-wired with a mains supply
cable.
A spare strain relief block is supplied in case
the pre-wired cable is not used.
The mains supply to the boiler must be either:
• The mains electrical supply to the boiler and system
wiring centre must be common and through either a
common fused double pole isolator or a fused three
pin plug and unswitched socket.
• The isolator shall be situated next to the boiler for
new systems and, where practicable, replacement
boilers.
• The isolator must have a contact separation of 3mm
minimum between all poles. Any system connected to
the boiler must not have a separate electrical supply.
• Use a 3A fuse in both situations.
ACCESS TO ELECTRICAL CONNECTIONS:
B Remove boiler casing to access control panel.
Refer to figure 46.
1. Remove the screw securing the control panel.
2. Lower the control panel into the horizontal service
position.
1.
2.
Fig. 46 Moving control panel into the service position
When stripping wires always ensure copper
strands do not fall into the control box.
34
Refer to figure 47.
1. Unscrew the three screws in the control panel.
2. Remove the connections cover.
1.
Fig. 47 Removing the connection cover
B Pass the 230 V mains power cable, from the control
box, through the grommet at the right hand side of the
pre-plumbing manifold and route to the mains isolator
next to the boiler.
SI1
Fuse F1 2.5A
SI2
Fuse F2 0.5A
SI3
Fuse F3 1.5A
ST6
Frost thermostat connection
ST10
Mains in & external controls connections
Tab. 20
ST10
SI1
SI3
Fig. 48 Electrical connector information
6 720 644 741a (2010/10)
1.
2.
1.
ST6
SI2

Hide quick links: