en | On-Screen Display (OSD) Menus (Bosch Protocol)
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows
you to configure a rule from previously-defined alarm inputs and outputs. Once an alarm is
configured with valid inputs and outputs, it can be turned on or off (enabled or disabled)
through its configuration menu.
Rule # Choices:
Enabled
Turns the rule on or off after its inputs and outputs have been defined.
YES to enable or NO to disable (default setting)
Input
Toggles through a list of valid inputs set in the Alarm I/O Setup > Inputs Setup Menu that
define the rule's inputs. A rule can have up to four (4) inputs.
Ilnputs which were set in the Inputs Setup Menu include Aux On/Off (1-64), Shot, and NONE
(default setting).
Output
Toggles through a list of valid outputs set in the Alarm I/O Setup > Outputs Setup Menu that
defines a rule's outputs.
Outputs set in the Outputs Setup Menu include Alarm Relay, Aux On/Off (1-64), Shot, OSD,
Transmit, and NONE (default setting).
Some outputs, such as Alarm Outputs 1-3, Alarm Relay, and Aux On/Off can be set to be
active for a specific duration of time as follows:
Seconds: 1-5, 10, 15, or 30
Minutes: 1-5 or 10
Latched: The alarm stays active until acknowledged.
Follows: The alarm follows the alarm rule.
Default setting: NONE
NOTICE!
You can include up to four (4) Input and Output events in a single rule. Each input and output,
however, must be true for the alarm's rule to be valid and enabled.
7.7

Diagnostics Menu

The Diagnostics menu contains a list of diagnostic tools and events. Most of these menu
items are display items only; you cannot select different values to change.
Exit...
Alarm Status...
BIST...
Internal Temp:
High Temp Events:
Highest Temp
Low Temp Events:
Lowest Temp:
Internal Humidity
Humidity Events
Security Access:
F.01U.276.622 | 1.0 | 2012.09
Diagnostics
Deg F / Deg C
Deg F / Deg C
Deg F / Deg C
Deg F / Deg C
Deg F / Deg C
%
0
0
Installation and User Manual
MIC Series 550 Classic Camera