INSPECTION

Always disconnect the battery cables from battery before
commencing electrical resistance test.
CONDENSER CHARGE COIL OUTPUT
 Peak Voltmeter Stevens CD-77
Tester range: POS 50
1. Disconnect the condenser charge coil lead wire connector.
2. Connect the tester probe to the coil lead wires as shown.
Tester probe connection
+ (Red)
Green
3. Remove the all spark plugs.
4. Crank with the recoil starter, then measure voltage.
Condenser charge coil output: 15 V or over
If measurement is out of specification, replace the condenser
charge coil.
CONDENSER CHARGE COIL RESISTANCE
 09930-99320: Digital tester
 Tester range: Ω (Resistance)
1. Disconnect the condenser charge coil lead wire connector.
2. Connect the tester probe to the coil lead wires as shown.
Tester probe connection
Probe
Green
Condenser charge coil resistance: 12.5 – 18.8 Ω
If measurement is out of specification, replace the condenser
charge coil.
- (Black)
Black/Red
Other probe
Black/Red
IGNITION AND ELECTRICAL 3-5
Black/Red
Green
1
Black/Red
Green
1