Cj-Series Configuration Units; Input Units - Omron NJ501-1 Series User Manual

Machine automation controller nj-series cpu unit hardware
Table of Contents

Advertisement

 CJ-series Configuration Units
CJ-series Basic I/O Units

Input Units

Name
Specifications
DC Input
Terminal block
Units
12 to 24 VDC, 8
inputs
Terminal block
24 VDC, 16 inputs
Fujitsu connector
24 VDC, 32 inputs
MIL connector
24 VDC, 32 inputs
Fujitsu connector
24 VDC, 64 inputs
MIL connector
24 VDC, 64 inputs
AC Input
Terminal block
Units
200 to 240 VAC,
8 inputs
Terminal block
100 to 120 VAC,
16 inputs
Interrupt
Terminal block
Input Unit
24 VDC, 16 inputs
Quick-
Terminal block
response
24 VDC, 16 inputs
Input Unit
B7A Inter-
64 inputs
face Units
*1 This is the input response time when no filter (i.e., 0 ms) is set. There is no filter setting for the CJ1W-
INT01/IDP01. (The time is always 0 ms.)
*2 The cable-side connector is not provided with Units equipped with cables. Purchase the connector separately
(Refer to 4-4-4 Wiring CJ-series Basic I/O Units with Connectors.), or use an OMRON Connector-Terminal
Block Conversion Unit or I/O Relay Terminal (Refer to 4-4-5 Connecting to Connector-Terminal Block Conver-
sion Units or I/O Relay Terminals.).
*3 An Interrupt Input Unit can be connected only in a CPU Rack. These Units must be mounted to slots 0 to 4 on
the CPU Rack. An Incorrect Unit/Expansion Rack Connection error (major fault level Controller error) will occur
if an Interrupt Input Unit is connected in other slots on the CPU Rack or to any slots on an Expansion Rack. Up
to two Interrupt Input Units can be connected.
*4 Interrupt Input Units can be used as normal Basic I/O Units. They cannot be used to start I/O interrupt tasks.
NJ-series CPU Unit Hardware User's Manual (W500)
Number
Model
of bits
allocated
CJ1W-ID201
8
CJ1W-ID211
16
CJ1W-ID212
16
*2
32
CJ1W-ID231
32
*2
CJ1W-ID232
*2
32
CJ1W-ID233
*2
64
CJ1W-ID261
*2
64
CJ1W-ID262
CJ1W-IA201
8
CJ1W-IA111
16
16
*3, *4
CJ1W-INT01
CJ1W-IDP01
16
CJ1W-B7A14
64
2 System Configuration
Current con-
*1
Response time
sumption (A)
ON
OFF
5 VDC
20 s
400 s
0.08
max.
max.
20 s
400 s
0.08
max.
max.
15 s
90 s
0.13
max.
max.
20 s
400 s
0.09
max.
max.
20 s
400 s
0.09
max.
max.
15 s
90 s
0.20
max.
max.
120 s
400 s
0.09
max.
max.
120 s
400 s
0.09
max.
max.
10 s
40 s
0.08
max.
max.
10 s
40 s
0.09
max.
max.
0.05 ms
0.5 ms
0.08
max.
max.
0.05 ms
0.5 ms
0.08
max.
max.
---
---
0.07
Weight
24 VDC
---
110 g max.
---
110 g max.
---
110 g max.
---
70 g max.
---
70 g max.
---
70 g max.
---
110 g max.
---
110 g max.
---
130 g max.
---
130 g max.
---
110 g max.
---
110 g max.
---
80 g max.
2-13
2

Advertisement

Table of Contents
loading

Table of Contents