Repacking The Blackdiamond 8806 Chassis - Extreme Networks BlackDiamond 8806 Hardware Installation Manual

Hide thumbs Also See for BlackDiamond 8806:
Table of Contents

Advertisement

Repacking the BlackDiamond 8806 Chassis

To repack the BlackDiamond 8806 chassis:
1 Attach the ESD-preventive wrist strap to your bare wrist and connect the metal end to the ground
receptacle on the chassis front panel.
2 Remove all modules and power supplies from the BlackDiamond 8806 chassis. Follow correct
Extreme Networks procedures for removing components.
3 Using four rack mounting screws, attach the 19-inch support bracket to the equipment rack
immediately below the chassis.
4 Remove the eight rack mounting screws that secure the chassis to the equipment rack.
5 Slowly guide the chassis out of the equipment rack using the support bracket for support.
6 Carefully lift the chassis off the support bracket and lower it onto the foam cushion in the shipping
carton base (see
Figure
To lift the chassis, on each side of the chassis, place one hand in the empty power supply bay and
the other hand in the recessed hand-hold on the back panel of the chassis.
CAUTION
Do not use the fan tray handle to lift or maneuver the BlackDiamond 8806 chassis. This handle is not
designed to support the weight of the chassis.
Figure 127: Setting the BlackDiamond 8806 Chassis onto the Foam Cushion
BlackDiamond 8800 Series Switches Hardware Installation Guide
127.)
EX_129
169