Environmental Limits; Table 14. Intel - Intel SS4000-E Technical Product Specification

Entry storage system
Hide thumbs Also See for SS4000-E:
Table of Contents

Advertisement

Intel® Entry Storage System SS4000-E
7.3

Environmental Limits

The following table summarizes environmental limits, both operating and non-operating.
®

Table 14. Intel

Entry Storage System SS4000-E Operating and Non-Operating Environmental
Temperature
Non-operating
Operating Temperature
Thermal Map
Thermal Shock
Non-operating
Humidity
Non-operating
Vibration
Non-Operating:
Shock
Non-operating
ESD
Operating
EMI
Operating
Revision 1.2
Limits
Specification
-40 degrees celcius to 70 degrees celcius
10 degrees celcius to 35 degrees celcius
Must not exceed maximum Integrated Circuit (IC) junction temperature as specified
in the component data sheets (CPDs).
Specification
-40 degrees celcius to 70 degrees celcius
Specification
90% Relative Humidity (RH) at +35 degrees celcius
Specification
2.2 Grms 5-500Hz for the unpackaged and 1.09 Grms 5-500Hz for the
packaged.
Specification
25 G, 11 millisecond (msec)
Specification
Test (air) to 15 KV and (contact) to 2-8KV with limited errors.
Specification
Required to meet EMI emission requirements, tested as part of system.