Environmental Limits; System Office Environment; System Environmental Testing; Table 13. Intel - Intel SS4000-E Technical Product Specification

Entry storage system
Hide thumbs Also See for SS4000-E:
Table of Contents

Advertisement

Environmental Limits

7.
Environmental Limits
7.1

System Office Environment

®

Table 13. Intel

Parameter
Operating Temperature
Non-Operating Temperature
Non-Operating Humidity
Acoustic noise
Operating Shock
Package Shock
Electrostatic Discharge (ESD)
System Cooling Requirement
in British Thermal Units (BTU)
per Hour
7.2

System Environmental Testing

The system has been tested per the Intel
number 662394-06. These tests include:
Temperature Operating and Non-Operating
Humidity Non-Operating
Packaged and Unpackaged Shock
Packaged and Unpackaged Vibration
AC Voltage, Frequency and Source Interrupt
AC Surge
Acoustics
ESD
EMC Radiated Investigation
40
Entry Storage System SS4000-E System Office Environment Summary
10 degrees celcius to +35 degrees celcius with the maximum rate of
change not to exceed 10 degrees celcius per hour.
-40 degrees celcius to +70 degrees celcius
90%, non-condensing at 35 degrees celcius
4.7 BA in an idle state at typical office ambient temperature. (23 ±
degrees celcius)
No errors with a half sine wave shock of 2 Giga (1.024 x 10
11 millisecond duration)
Operational after a 30 inch free fall, although cosmetic damage may be
present (chassis weight 30 lbs)
±15 Kilovolt (KV) per Intel
< 680 BTU/hour
®
Intel® Entry Storage System SS4000-E
Limits
®
Environmental test specification
Environmental Standards Handbook, Intel document
9
) (G) (with
Revision 1.2