System Level Environmental Limits; Table 1. System Environmental Limits Summary - Intel JBOD2312S3SP Hardware Manual

Table of Contents

Advertisement

2.2 System Level Environmental Limits

The following table defines the system level operating and non-operating environmental limits.
Parameter
Operating
Temperature
Shipping
Altitude
Operating
Humidity
Shipping
Operating
Unpackaged
Shock
Packaged
Unpackaged
Vibration
Packaged
Voltage
Frequency
Source Interrupt
Surge
AC-DC
operating
operating
Line to earth Only
Air Discharged
ESD
Contact Discharge
Power in Watts
Acoustics Sound
Servers/Rack
Power Measured
Mount BA
System 460W Redundant Power Supplies (CRPS) operate in spread-core flow conditions (positive pressure
to the power supply's inlet) and incorporate a 40mm fan for its own thermal management. To ensure PS
thermal protection under all operating conditions the fan speed control has a closed loop algorithm based
on both the critical component temperature and the ambient temperature (inlet temperature). The PS over
Temperature Protection (OTP) protects against over temperature conditions created by the loss of fan
cooling or excessive ambient temperature. In an OTP condition the PS will shut down and restore power
1
Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to
cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully
integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who
chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the
amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if
components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.
4
Intel® Storage Server System JBOD2312S3SP Hardware Guide

Table 1. System Environmental Limits Summary

ASHRAE Class A2 – Continuous Operation. 10ºC to 35ºC
maximum rate of change not to exceed 10ºC per hour.
ASHRAE Class A3 – Includes operation up to 40ºC for up to 900 hrs per year.
ASHRAE Class A4 – Includes operation up to 45ºC for up to 90 hrs per year.
-40ºC to 70ºC (-40ºF to 158ºF)
Support operation up to 3050m with ASHRAE class deratings.
50% to 90%, non-condensing with a maximum wet bulb of 28ºC (at temperatures from
25ºC to 35ºC)
Half sine, 2g, 11 mSec
Trapezoidal, 25g, velocity change is based on packaged weight
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
5 Hz to 500 Hz
5 Hz to 500 Hz
90 V AC to 132 V AC and 180 V AC to 264 V AC
47 Hz to 63 Hz
No loss of data for power line drop-out of 12 mSec
Non-
Unidirectional
and
AC Leads
I/O Leads
DC Leads
12.0 kV
8.0 kV
<300 W
≥300 W
7.0
7.0
Limits
2.20 g RMS random
1.09 g RMS random
2.0 kV
1.0 kV
0.5 kV
≥600 W
≥1000 W
7.0
7.0
1
1
(50ºF to 95ºF) with the

Advertisement

Table of Contents
loading

Table of Contents