Environmental Limits

7.
Environmental Limits
7.1

System Office Environment

Table 18. Intel
Parameter
Operating Temperature
Non-Operating Temperature
Non-Operating Humidity
Acoustic noise
Operating Shock
Package Shock
Electrostatic Discharge (ESD)
System Cooling Requirement
in British Thermal Units (BTU)
per Hour
7.2

System Environmental Testing

The system has been tested per the Intel
number 662394-03. These tests include:
Temperature Operating and Non-Operating
Humidity Non-Operating
Packaged and Unpackaged Shock
Packaged and Unpackaged Vibration
AC Voltage, Frequency and Source Interrupt
AC Surge
Acoustics
ESD
EMC Radiated Investigation
36
®
Storage System SSR212MA System Office Environment Summary
10 degrees celcius to +35 degrees celcius with the maximum rate of
change not to exceed 10 degrees celcius per hour.
-40 degrees celcius to +70 degrees celcius
95%, non-condensing at 35 degrees celcius
7.0 BA (Rackmount) in an idle state at typical office ambient
temperature. (23 ± degrees celcius)
No errors with a half sine wave shock of 2 Giga (1.024 x 10
11 millisecond duration)
Operational after a 30 inch free fall, although cosmetic damage may be
present (chassis weight 30 lbs)
±15 Kilovolt (KV) per Intel
2275 BTU/hour
®
Environmental Standards Handbook, Intel document
Revision 1.4
Intel® Storage System SSR212MA
Limits
®
Environmental test specification
9
) (G) (with