Removing Range Lever Upper Spring
(Figure 4-43)
Release spring so that both ends rest on back wall of camera body. Remove screw and
spring.
Range Lever Upper
Parallax
Range Lever
Relay Lever
Upper Spring
Middle Lever
Screw
Back Wall
Spring
Camera Body
Camera
Back Wall
Body
Figure 4-43. Removing range lever upper spring
Removing Middle Lever
(Figure 4-44)
Release spring. Use blade of screwdriver to remove middle lever shaft.
Note: Changing middle lever eccentric adjustment will require readjustment of VF/RF
near range setting.
Pull middle lever from shaft. Remove two Phillips head screws. Lift off base plate.
Removing Camera Body Sealing Sponges
(Figure 4-45)
The back sealing sponge is accessible after film holder has been removed (Figure 4-1).
Remove front panel as shown in Figure 4-36. The sponges are cemented in place. Use 1/8"
(.33cm) chisel to scrape sponge and cement from groove; clean with trichloroethylene
thoroughly before replacing sponges.
56