Shutter Cocking Lever; Removal; Replacing Shutter Cocking Lever - Polaroid M402b Repair Manual

Miniportrait camera
Table of Contents

Advertisement

M402b MiniPortrait Camera Repair Manual

Shutter Cocking Lever

Removal

1. Remove the front cover assembly (Figure 2-1).
2. Using a pair of small needle nose pliers, gently remove the clip and washer that
secure the return spring to the plastic post at the lower end of the shutter cocking
lever.
If necessary, use an Xacto knife to cut away the top of the plastic post so that
the clip and washer can be removed easily.
Note: While removing the shutter cocking lever be careful not to misalign
the shutter and the diaphragm plates.
If the shutter and the diaphragm plates are misaligned during the
removal of the shutter cocking lever, refer to the Shutter and
Diaphragm Plate assembly/disassembly procedure to properly
realign (see page 24).
3. Remove the shutter cocking lever from the left shutter cocking guide being careful not to
misalign the shutter and the diaphragm plates.
Square
Cocking Slot
Plastic Post
(Figure 2-7)
Figure 2-7. Replacing shutter cocking lever
Left Shutter
Shutter
Cocking Guide
Cocking Lever
Camera Body
20
Disassembly/Assembly
Aperture
Drive Gear
Shutter Plate
Assembly
Right Shutter
Cocking Guide