Beverly 500 i.e.
The LED is turned on by the decoder.
The control unit data can be checked by the diag-
nostic tester.
Specific tooling
020680Y Diagnosis Tool
To connect the diagnostic tester, open the spark
plug inspection port and pull out the EMS Diagno-
sis socket. Remove the protection cap and con-
nect the tester terminal.
Power the diagnostic tester by connecting the ter-
minals to the battery poles, or the specific connec-
tor to the socket inside the gloves compartment.
Set the switch to "ON" and select the diagnostic
tester menu to the immobiliser function.
Scroll the pages to display the control unit data.
N.B.
AN UNPROGRAMMED SYSTEM CANNOT BE DETECTED UPON FIRST FITTING, OR IN CASE
THE DECODER AND THE CONTROL UNIT ARE REPLACED CONCURRENTLY.
The information will be as follows:
Unprogrammed control unit «ON»
Start-up disabled «ON»
Key number Zero › 250
Injection
INJEC - 217