Cabinet And Countertop Preparation - Electrolux E30GF74GPS Technical & Service Manual

30 and 36 inch all gas range
Hide thumbs Also See for E30GF74GPS:
Table of Contents

Advertisement

CAbINET AND COUNTERTOP PREPARA-
TION
Check your local building codes for the proper method
of installation. In the absence of local codes, this ap-
pliance should be installed in accordance with the
National Fuel Gas Code ANSI z223.1/NFPA 54. In Can-
ada, installation must conform to current Natural Gas
Installation Code, CAN1-1.1-M and the local codes
where applicable. This range has been design-certified
according to ANSI z21.1b-2003, latest edition. Be cer-
tain that the appliance being installed is correct for the
gas service being provided. Refer to the rating label
located on the kick panel and/or the table in this manual
for gas supply requirements.
All dimensions shown are based on standard Ameri-
can cabinets, 36 inches (914mm) high at the finished
countertop by 24 inches (610mm) deep, with a 25 inch
(635mm) overall countertop depth. When installing
the range into nonstandard cabinets, minimum clear-
ances shown in the diagrams in this manual must be
maintained.
Carefully check the location where the range is to be
installed. For best performance, the range should be
placed away from drafts that may be caused by doors,
windows and HVAC outlets.
NOTES
• If cabinet storage space is to be provided
directly above the range, the risk of personal
injury may be reduced by installing a
ventilating hood that projects horizontally a
minimum of 5 inches beyond the face of the
cabinets.
• The range may be installed flush to the rear
wall. we recommend installing a
noncombustible material on the rear wall
above the range and up to the vent hood. It is
not necessary to install noncombustible
materials behind the range below the
countertop height.
• The minimum distance from the sides of the
range above the countertop to combustible
side walls must be at least 10 inches.
• All models are delivered with a 3.5"
backguard from the factory. A 9"
backguard is available on the E36GF75GPS
AND E36GF76GPS as options.
• Utilities may be located: In the lower left
corner of the adjacent right cabinet. (Refer to
Figure 2)
IMPORTANT
• Contact your local building department to
verify compliance with local code
interpretation.
41