Gas And Electrical Rough-In; Locations - Electrolux E30GF74GPS Technical & Service Manual

30 and 36 inch all gas range
Hide thumbs Also See for E30GF74GPS:
Table of Contents

Advertisement

GAS AND ELECTRICAL ROUGH-IN

Locations

A manual shut valve must be installed in the gas piping,
external to the appliance, for the purpose of turning on
or shutting off gas to the appliance. Place the location
of the range and the gas supply to allow access to the
valve when the unit is installed. Access to the remote
circuit breaker panel/fuse box, with the range in place,
must also be allowed for in the installation. Any open-
ings in the wall behind the appliance and in the floor
under the appliance must be sealed. Both the gas sup-
ply piping and shut-off valve, and the electrical junction
box/receptacle must be located so they do not interfere
with the range when it is installed. In addition, the junc-
tion box must be located so the range can be removed
for service when the conduit supplied with the unit is
attached to the junction box. Do not lengthen the con-
duit or wiring provided with the range.
NOTES
The areas shown in the illustrations, denote the
location of the gas stub and the electrical junction
box/receptacle. These are suggested locations. For
replacement purposes, the location of the existing
utilities may be utilized provided that they do not
interfere with the sides or rear of the range. I f in-
stalling the gas valve behind the range, verify that
local building codes will permit this.