Cabinet And Countertop Preparation - Electrolux E30GF74GPS Installation Instructions Manual

Gas range
Hide thumbs Also See for E30GF74GPS:
Table of Contents

Advertisement

10
Preparing for Installation

CABINET AND COUNTERTOP PREPARATION

Check your local building codes for the proper method of installation. In the
absence of local codes, this appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada, installation must
conform to current Natural Gas Installation Code, CAN1-1.1-M and the local codes
where applicable. This range has been design-certified according to ANSI Z21.1b,
latest edition. Be certain that the appliance being installed is correct for the gas
service being provided. Refer to the rating label located on the kick panel and/or the
table on page 7 for gas supply requirements.
All dimensions shown are based on standard American cabinets, 36 inches
(914mm) high at the finished countertop by 24 inches (610mm) deep, with a 25
inch (635mm) overall countertop depth. When installing the range into nonstandard
cabinets, minimum clearances shown in the diagrams on page 11 must be
maintained.
Carefully check the location where the range is to be installed. For best
performance, the range should be placed away from drafts that may be caused by
doors, windows and HVAC outlets.
NO
NO
TES
TES
NO
NO
NOTES
TES
TES
If cabinet storage space is to be provided directly above the range, the risk of
personal injury may be reduced by installing a ventilating hood that projects
horizontally a minimum of 5 inches beyond the face of the cabinets.
The range may be installed flush to the rear wall. We recommend installing a
noncombustible material on the rear wall above the range and up to the vent
hood. It is not necessary to install noncombustible materials behind the range
below the countertop height.
The minimum distance from the sides of the range above the countertop to
combustible side walls must be at least 10 inches..
All models are delivered with a 3.5" backguard from the factory. A 9" backguard
is available on the E36GF75GPS AND E36GF76GPS as options.
Utilities may be located: In the lower left corner of the adjacent right cabinet.
(Refer to Figure 2)
I M P O R
I M P O R
I M P O R T T T T T A N T
I M P O R
I M P O R
Contact your local building department to verify compliance with local code
interpretation.
A N T
A N T
A N T
A N T

Advertisement

Table of Contents
loading

This manual is also suitable for:

E36gf75gpsE36gf76gps

Table of Contents