Electrical Operation Of The Convection Fan Motor - Electrolux E30GF74GPS Technical & Service Manual

30 and 36 inch all gas range
Hide thumbs Also See for E30GF74GPS:
Table of Contents

Advertisement

Electrical operation of the convection fan
motor
The convection fan motor circuit is made up of the
convection fan switch,
the convection fan relay
L
Fans switch
Convection fan
relay contacts
Convection fan
relay coil
BR
C
Thermostat
58
and the convection fan motor.
When electrical power is applied to the range, power
is applied to one side of the convection fan switch.
When the convection fan switch is pushed, closing the
contacts of the switch, powers applied to the contacts
of the convection fan motor relay. The context of the
convection fan relay are normally closed when the
relay is de-energized. From the contacts of the relay
powers applied to the convection fan motor causing the
fan motor to run. The convection fan relay is placed in
the circuit to prevent the convection fan from operating
when the broiler burner is operating.
Convection
fan motor
Broiler
Broiler
igniter
safety valve

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E36gf75gpsE36gf76gE36gf76gps

Table of Contents