Initial start-up
2.1.8
Adjusting the hot-water temperature for external
tanks
Use the hot-water temperature regulator to adjust the
temperature (fig. 33, item 5) to the desired setting table 6.
2.1.9
Adjust the hot-water flow controller (applies to
combi-unit 600 - 24C only)
Adjust the hot-water flow controller (fig. 34) to the desired
setting:
– To increase the flow of hot water:
turn valve towards "+".
– To reduce the flow of hot water:
turn valve towards "-".
NOTE
The unit is factory-adjusted to an output of
22 kW and a flow of 7 l/min
2.1.10 Setting the heating capacity
Set the heating capacity (table 7), according to the amount of
heat required, at the controller (fig. 33, item 4).
NOTE
The controller is factory-adjusted to position "6"
Controller setting
1
2
3
4
5
6
7
8
9
10
Table 7
Heating capacity
Subject to modifications resulting from technical improvements!
26
Installation and maintenance instructions for wall-mounted condensing gas boiler 600 - 11S/19S/24S/24C • 05/2004
600 - 11 S
600 - 19 S
4.9
5.6
6.3
6.9
7.6
8.3
9.0
9.6
10.3
11.0
Fig. 34 Hot-water flow controller
Heating capacity [kW] (±5 %)
600 - 24 S
9.7
10.7
11.3
11.8
12.9
12.8
14.5
13.8
16.0
14.9
17.6
15.9
19.2
16.9
20.8
18.0
22.4
19.0
24.0
Boulter Buderus Ltd. • http://www.boulter-buderus.co.uk
+
600 - 24 C
9.7
9.7
11.3
12.9
14.5
16.0
17.6
19.2
20.8
22.4
24.0