3.6.2 INSTALLATION PROCEDURE

A688I401.WMF
[C]
A688I500.WMF

CAUTION
Unplug the main machine power cord before starting the following
procedure.
1. Unpack the bridge unit. Then remove the tapes.
2. Remove the inner tray [A].
3. Remove three covers [B].
If the optional external output tray (A825) will be installed instead of a
finisher, do step 4.
4. Remove the two covers [C].
5. Remove the cover [D] (1 screw).
6. Remove the cap [E].
SM
BRIDGE UNIT INSTALLATION
[A]
[B]
3-23
[D]
[E]
A688I407.WMF