Page Table; Initialization Of 8, C, 13, 18, 1C Page Data - Sony HVR-Z1J Service Manual

Digital video camera recorder
Hide thumbs Also See for HVR-Z1J:
Table of Contents

Advertisement

Ver. 1.7 2007. 10
The changed portions from
Ver. 1.6 are shown in blue.

3. 8 Page Table

Note1: The data of page: 0, address: 10 must be "00".
Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C,
13, 18, 1C Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of 8, C,
13, 18, 1C Page Data").
Note3: Mechanism control microprocessor ver. 3.0 (MP3).
(Refer to "1. Initialization of 8, C, 13, 18, 1C page data".)
Note4: Mechanism control microprocessor ver. 4.0 (MP4) or ver. 5.0
(MP5) or ver. 6.0 (MP6) or ver. 7.0 (MP7) or ver. 8.0 (MP8).
(Refer to "1. Initialization of 8, C, 13, 18, 1C page data".)
Note5: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value. Refer to
"1. Initialization of 8, C, 13, 18, 1C page data" for .the version
check of the mechanism control microprocessor.Table. 6-1-6.
Address
Initial value
00 to 11
12
13 to 3D
3E
3F
78 to 7D
7E
7F to 83
84
85
40 or 50
86 to 9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9 to AC
AD
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (Mechanism control
microprocessor ver. 3.0 (MP3) or ver.
4.0 (MP4) )
Fixed data-1 (Mechanism control
microprocessor ver. 5.0 (MP5) or ver.
6.0 (MP6) or ver. 7.0 (MP7) or ver.
8.0 (MP8))
Fixed data-1
Fixed data-2 (Mechanism control
microprocessor ver. 3.0 (MP3) or ver.
4.0 (MP4))0
Fixed data-1 (Mechanism control
microprocessor ver. 5.0 (MP5) or ver.
6.0 (MP6) or ver. 7.0 (MP7) or ver.
8.0 (MP8))
Fixed data
40: Mechanism control
microprocessor ver. 3.0 (MP3) or ver.
4.0 (MP4) or ver. 5.0 (MP5)
50: Mechanism control
microprocessor ver. 6.0 (MP6) to ver.
8.0 (MP8)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Address
Initial value
AE to B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE to BF
C0
C1
C2
C3
C4
C5
C6 to C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4 to FF
6-12
Remark
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Fixed data-2 (Note3)
Fixed data-1 (Note4)
Fixed data-1
Table. 6-1-6.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-z1uHvr-z1nHvr-z1eHvr-z1pHvr-z1c

Table of Contents