Adjusting label sensor

Access only when service key is inserted!
You can adjust the label sensor with the Adj. gap sensor function. This is necessary if the sensor or
CPU PCB has been changed.
Carry out adjustment of the sensor with the cover closed and housing mounted to keep out external light
sources.
1. Insert service key into a USB master interface.
2. Press the menu button.
3. Select Service > Adj. gap sensor menu.
4. Press the ↵ button.
5. Open printhead.
In the display you are instructed remove the label medium from the sensor via the Remove labels
message.
6. Remove label medium from the sensor.
7. Press the ↵ button.
In the display you are instructed to load the liner into the label sensor via the Insert liner mes-
sage.
8. Load liner (without labels) into the sensor.
9. Ensure that no labels are found on the liner near the sensor. Otherwise, the result will be faulty adjust-
ment and device malfunction.
10.Start adjustment of the label sensor with the ↵ button.
OK appears in the display after a successful adjustment.
11.Confirm completion of the adjustment with the ↵ button.
Error during adjustment:
If an error occurs while adjusting the label sensor, Error appears in the display. If an error occurs again
when repeating the adjustment, one of the following assemblies may be defective:
Label sensor
Connection cable of the label sensor
CPU PCB