Table 3-3. Control Panel LED Does Not Light On.
Cause
Check Point
Blowout of a fuse on
Is a fuse on the power
the power board.
board blown out?
Are connectors
Connector is not
connected to the
connected to the
power board
power board.
properly?
Power switch is
Is conductivity of the
defective.
switch is OK?
Are +5VDC and
Power board is
+35VDC OK when
defective.
the power is on?
Power board and the
Is CN8 connected
main board are not
properly?
connected properly.
Main board is
-
defective.
Control panel harness
Is the harness of the
is not connected
control panel
properly.
connected properly?
Control panel board
or harness is
-
defective.
Table 3-4. Printer Mechanism Does Not Operate.
Cause
Check Point
Any of CN3 to CN12
Are all connectors
is not connected to the
connected properly?
main board properly.
Main board is
-
defective.
Printer mechanism is
-
defective.
Troubleshooting
Y/N
Solution
Check the electric circuit and
YES
printer mechanism. If there is no
short circuit, replace the fuse.
NO
Replace the power board.
YES
Replace the power board.
NO
Replace the power board.
NO
Connect CN8 properly.
-
Replace the main board.
NO
Connect the harness properly.
-
Replace the control panel.
Y/N
Solution
NO
Connect them properly.
-
Replace the main board.
-
Replace the printer mechanism.
Troubleshooting
Table 3-5. When Power is Applied, the Printer Becomes Fatal Error.
Cause
Check Point
Are CR motor, timing
Carriage home
belt, and CR home
position error
position sensor
(CR Error=30H)
normal?
CG access error
Is main board
(CG Error=32H)
normal?
Abnormal printhead
voltage
Is printhead voltage
(Head Low Volt
(+42V line) normal?
Error=33H)
Abnormal printhead
Is the printhead
temperature
connected to the main
(Head Open
board properly?
Error=3AH)
CR motor harness is
Is CR motor harness
not connected
CN10 connected
properly.
properly?
CR motor is defective.
-
HP detector harness is
Is HP detector
not connected
harness CN3
properly
connected properly?
HP detector is
-
defective.
Power board is
Is power voltage
defective.
normal?
-
-
Revision D
Y/N
Solution
Replace the power supply circuit
YES
board.
NO
Replace the defective component.
See Table 3-10, "Electrical Noise is
YES
Caused.," on page 62.
NO
Replace the main board.
YES
Replace the printhead.
NO
Replace the power supply board.
YES
Replace the printhead.
NO
Connect the FFC properly.
NO
Connect it properly.
-
Replace the CR motor.
NO
Connect it properly.
-
Replace the HP detector.
NO
Replace the power board.
Replace the main board and printer
-
mechanism.