F. Vent Kits Components
Direct Vent Flex Liner Accessory Kits (see Figure 8.9)
LINK-DV30B: Masonry 3 in. (76 mm) flex liner kit. Expands
to 30 ft. (9 m). Includes: two liners, termination cap,
flashing, and link adapter.
Flash-Damp: Zero clearance damper flashing kit for use
with the LINK-DV30B liner kit.
LINK-ZC-ADP: Zero clearance chimney adapter
DV-46DVA-GK: Adapter kit. It is permissible to use DV-
46DVA-GK to connect collinear flex vent to SLP vent pipe
to extend the run.
FLEX3-30: One 3 in. (76 mm) flexible liner expands to 30
ft. (9 m).
FLEX-CNCT: Connector kit - 3 in. (76 mm) liner to 3 in. (76
mm) liner, one connector per kit.
LINK-DV30B
FLASH-DAMP
DV-36DVA-GK
Figure 8.9 Direct Vent Flex Liner Accessory Kits
FLEX3-30
LINK-ZC-ADP
FLEX-CNCT
Heat & Glo • Cosmo-I30AU • 2243-900 Rev. W • 10/14
G. Alternate Venting Configurations Using
Adaptation to SLP Venting:
This model is approved to use SLP Series flue pipe com-
ponents. A SLP-TVHW vertical Termination Cap must be
used for vertical terminations. A SLP-TRAP2 can be used
for horizontal terminations.
Approved flue system components are labeled for identifi-
cation. NO OTHER FLUE SYSTEMS OR COMPONENTS
MAY BE USED. Detailed installation instructions are in-
cluded with each flue termination kit and should be used
in conjunction with this manual.
WARNING! Risk of Fire! This gas appliance and flue
assembly must be flued directly to the outside and must
never be attached to a chimney serving a separate solid
fuel burning appliance. Each gas appliance must use a
separate flue system-common flue systems are prohibited.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping material could ignite and will in-
terfere with proper operation of doors and louvers.
• Horizontal sections 3 in. (76 mm) from the top of the
pipe.
• Horizontal sections 2-1/2 in. (64 mm) at wall shield
firestops.
• Horizontal sections 1 in. (25 mm) from sides and bottom
of the pipe.
• Vertical sections 1 in. (25 mm) on all sides of pipe.
Failure to keep insulation or other material away from vent
pipe may cause over heating and fire.
For alternative installations, other than depicted, contact
your dealer for further information.
29