Heat & Glo COSMO-I30-IFT Installation Manual
Hide thumbs Also See for COSMO-I30-IFT:
Table of Contents

Advertisement

Quick Links

CAUTION! Risk of Fire! DO NOT store instruction manuals inside fireplace cavity. High temperatures
could cause a fire.
INSTALLER: Leave this manual with the appliance, not inside the appliance.
CONSUMER: Retain this manual for future reference. Do not store inside the appliance
NOTICE: DO NOT discard this manual!
Models:
COSMO-I30-IFT
COSMO-I35-IFT
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Pour demander un exemplaire en français de ce manuel
d'installation, visitez www.quadrafire.com.
Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo COSMO-I30-IFT

  • Page 1 Pour demander un exemplaire en français de ce manuel d’installation, visitez www.quadrafire.com. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 2: Table Of Contents

    G. Installing Termination Cap ......27  = Contains updated information. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________  = Contains updated information. (Builder / Gen. Contractor/) (Installer) (Date) 2535-982B 6/23 Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 4: Product Specific And Important Safety Information

    State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 5: Getting Started

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 6 Multi-purpose tool can be stored in appliance manual bag. Figure 2.3 Multi-Purpose Tool Storage Options DO NOT store appliance manual bag in or around the appliance. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 7: Good Faith Wall Surface

    Stove cement / Aluminum foil tape 3/16 in. Allen wrench (Rear Leveling Legs) Elongated pressure taps (Recommended) Noncorrosive leak check solution Caulking material (300 ºF minimum continuous exposure rating) Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 8: Appliance/Decorative Barrier Front Dimension Diagrams

    18-15/16 481 21-7/16 545 2-7/16 2-7/16 *Note: Location G is the appliance depth measurement, for installation depth reference Location E on Figure 3.9. Figure 3.1 Appliance Dimensions Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 9 27-5/8 16-1/16 1-7/8 30-5/8 20-1/2 COSMO-I30-IFT INFIT-30 32-5/8 19-9/16 1-7/8 35-5/8 23-1/2 COSMO-I35-IFT INFIT-35 Figure 3.2 Decorative Barrier Front Dimensions - Inside Fit Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 10 NOTICE: 1/2 inch gap must be maintained or components will overheat. 32-5/16 19-1/2 2-1/4 23-1/2 COSMO-I30-IFT FS-MI30 37-5/16 23-1/2 2-1/4 26-1/2 COSMO-I35-IFT FS-MI35 1041 Figure 3.3 Decorative Barrier Front Dimensions - Firescreen Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 11 28-9/16 17-1/16 2-3/8 23-1/2 COSMO-I30-IFT IA-MI30 33-9/16 20-1/2 2-3/8 26-1/2 COSMO-I35-IFT IA-MI35 1041 Figure 3.4 Decorative Barrier Front Dimensions - Iron Age Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 12 31-3/8 15-9/16 3-7/8 36-1/4 23-1/2 COSMO-I30-IFT HARC-MI30 36-3/8 19-1/16 3-7/8 41-1/4 26-1/2 COSMO-I35-IFT HARC-MI35 1048 Figure 3.5 Decorative Barrier Front Dimensions - Halston Arch Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 13: Minimum Fireplace Opening

    1/2 in. Figure 3.8 Minimum Required 1/2 in. Gap NOTICE: 1/2 inch gap must be maintained or components will overheat. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 14 On site custom surrounds are available. See your dealer for information. On site custom surrounds are flush and have no depth. A flush surround would increase the unit opening depth (E*) by 3/4 inch. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 15: Zero Clearance Wall Extension

    Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of decorative barrier fronts. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 16 Note: Combustible materials may be used to seal wall extension to existing masonry wall as long as it is out- side the non-combustible zone. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 17: Mantel, Wall Projections, & Hearth Extensions

    Note: All numbers in Tables 1 and 2 include the 1/4 in. gap on surround edge. SURROUND OPENING MANTEL LEG OR WALL PROJECTIONS Figure 3.14 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of surround opening) Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 18: Hearth Extension / Vinyl Flooring

    SURROUND Flooring & Hearth Material Flooring & Hearth Material Flooring & hearth material must remain below the bottom of surround Figure 3.18 Flooring & Hearth Material Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 19 70 °F). Consult the manufac- turer’s flooring specifications to ensure compatibility. COMBUSTIBLE FLOOR UNDERNEATH APPLIANCE Figure 3.20 Solid Fuel Floor Clearance Figure 3.19 Vinyl Flooring Recommendations Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 20: Installation Preparation

    Appliance Cord Length (approximate) Appliance Size Left Side Right Side 30 in. 10 ft. 3 in. 7 ft. 6 in. 35 in. 10 ft. 7 ft. Figure 4.1 Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 21: Installing Vent Pipe And Appliance

    VENT PIPE COLLAR SLIDE PLATE ASSEMBLY EXHAUST STARTING COLLAR NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. Figure 5.1 Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 22: Using Vertical Restrictor

    INLET AIR VENT PIPE NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. Figure 5.2. Min. / Max. Venting Requirement Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 23: Venting Components

    • Depending on the chimney cleanliness, consider using the full length intake so as to lessen the possibility of sense rod contamination and flame rectification issues. Figure 5.4. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 24: Connecting To Slp

    Up to four 45 degree elbows may be used as long as the minimum venting requirements are met per the above chart. Figure 5.5 Optional SLP Venting Configuration - Vertical Termination Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 25: Connecting Vent Pipe

    • Trim chimney top plate to minimize excess overhang or bend over flue tile. See Figure 5.6. • Place 3/8 inch bead of 300 ºF minimum continuous exposure rating silicone on flue tile top. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 26: Placing, Securing And Leveling The Appliance

    LOWER REAR LEVEL LEGS TO REDUCE GAP ABOVE SURROUND FLOOR Figure 5.7 Leveling Leg Detail Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 27: Installing Termination Cap

    Over 10/12 to 11/12 ..3.25 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 5.8 Minimum Height from Roof to Lowest Discharge Opening Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 28: Electrical Information

    NOTICE: DO NOT wire 110-120 VAC to wall switch. RECOMMENDED ELECTRICAL OUTLET LOCATIONS APPLIANCE Figure 6.1 Electrical Outlet Detail Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 29: Wiring Requirements

    JUMPER WIRE * SRV2187-198 BATTERY PACK 2532-301 APPLIANCE 2326-142 ON/OFF CONTROL (OPTIONAL) WSK-21-W * JUMPER WIRE AVAILABLE FROM YOUR LOCAL DEALER Figure 6.2 IntelliFire Touch Wiring Diagram Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 30: Installation / Service For Fan

    • Reinstall valve plate assembly, burner assembly, base pan assembly, logs and appliance glass and front. INSTALL FAN OPTION 2 Figure 6.5 Through Valve Plate Opening (Option 2) Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 31: Gas Information

    CAUTION: Any wires removed from the wire clips during appliance installation or service must be re-installed in the wire clips. GLASS GLASS CLIP CLIP ASSEMBY ASSEMBLIES SCREW ACCESS Figure 7.2 Glass Clip Assembly Removal Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 32: Gas Pressure

    1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Figure 7.4 Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 33: High Altitude Installations

    Figure 7.6 Gas Valve Detail Figure 7.5 Air Shutter Air Shutter Settings Propane COSMO-I30-IFT 1/2 in. Full Open COSMO-I35-IFT 3/8 in. Full Open Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 34: Finishing

    Note: All numbers in Tables 1 and 2 include the 1/4 in. gap on SURROUND OPENING MANTEL LEG OR surround edge. WALL PROJECTIONS Figure 8.1 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of surround opening) Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 35: Hearth Extension

    SURROUND Flooring & Hearth Material Flooring & Hearth Material Flooring & hearth material must remain below the bottom of surround Figure 8.5 Flooring & Hearth Material Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 36 16 in 30-3/4 in. 35 in. 16 in 35-3/4 in. SIDE VIEW MINIMUM 1/4 IN. REQUIRED COMBUSTIBLE FLOOR UNDERNEATH APPLIANCE Figure 8.7 Solid Fuel Floor Clearance Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 37: Appliance Setup

    WARNING! Glass seal plate must be properly installed. Risk of elevated component temps and carbon monoxide exposure. Note: Appliance is shipped with glass seal plate in the installed position. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 38: Remove The Shipping Materials

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories Figure 9.3 Remove Shipping Screws could result in a safety hazard and will void the warranty. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 39: Magic Glass Panels

    1. Position four (4) magic glass channels and screw into place. See Figure 3. Figure 4 Magic Glass Position in Channel MAGIC GLASS MAGIC GLASS CHANNELS CHANNELS Figure 3 Position four (4) Magic Glass Channels Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 40 Figure 5 Install Rear Glass Panel 3. Install left and right glass refractory panels by sliding them into the channels. Figure 6 All Glass Panels Installed 2535-951 Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 41: Glass Media / Stone Placement

    • Do NOT use any media other than the media supplied with this fireplace. • Do NOT exceed one layer of media on base pan. Fireplace will not function properly. Delayed ignition may occur. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 42: Install Decorative Barrier Front And Surround

    Figure 6.2. • Reset switch must be installed and in the “ON” position for appliance to operate. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 43: Appliance Break-In

    If this occurs, restart the appliance. NOTICE! Open windows for air circulation during fire- place break-in. • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 44: Reference Materials

    FLEX3-30: One 3 inch flexible liner expands to 30 feet. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...
  • Page 45: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2023 Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23...

This manual is also suitable for:

Cosmo-i35-ift

Table of Contents