Heat & Glo COSMO-I30AU Owner's Manual page 27

Hide thumbs Also See for COSMO-I30AU:
Table of Contents

Advertisement

MODEL
COSMO-I30AU
TABLE 1
TERMINATION CAP
EXHAUST
COLLAR
WARNING: THE EXHAUST PIPE MUST
ONLY BE CONNECTED TO THE EX-
HAUST STARTING COLLAR OF THE
UNIT AND THE EXHAUST COLLAR OF
THE TERMINATION CAP.
THE INLET AIR PIPE MUST ONLY BE
CONNECTED TO THE INLET AIR COL-
LAR OF THE UNIT AND ATTACHED
TO THE INLET AIR COLLAR OF THE
TERMINATION CAP. THE APPLIANCE
WILL NOT OPERATE PROPERLY IF
INCORRECTLY CONNECTED.
THIS IS A BALANCED FLUE HEATER
AND REQUIRES THE USE OF
BOTH FLUE LINERS AND MUST
TERMINATE TO THE CAP.
*
USE RESTRICTOR FOR VENT RUNS OVER 4.5 METERS. USE 57 MM FOR HORIzONTAL
TERMINATIONS AND 45 MM FOR VERTICAL TERMINATIONS.
Figure 8.8
CHIMNEY PLATE
(MADE TO ORDER)
INLET AIR
COLLAR
Heat & Glo • Cosmo-I30AU • 2243-900 Rev. W • 10/14
FLUE TERMINATION APPROVAL
LINK-DV30B
VERTICAL TERMINATION CAP
SLP-TVHW
FLEXIBLE FLUE
MINIMUM TOTAL FLUE
RUN 10 ft. (3 m)
MAXIMUM 39 ft. (12 m)
MINIMUM 1/4 in. (6 mm )
NON-COMBUSTIBLE BASE (UNDER UNIT)
*
27