Before Lighting Fireplace - Heat & Glo COSMO-I30AU Owner's Manual

Hide thumbs Also See for COSMO-I30AU:
Table of Contents

Advertisement

4. If you intend to use both an optional wired wall switch,
and the RC300 remote control to operate your fireplace,
the wall switch will override any commands given by
the remote.
MODULE
WIRE LEAD FROM
REGULATOR CONNECTS HERE
Figure 2.3 Control Module
5. Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying an error code at its status indicator LED.
• Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section G.
• Locate the module selector switch. (See Figure 2.3).
• Set the module selector switch to the OFF position.
• Wait five (5) minutes to allow possible accumulated gas
to clear.
• Set the module selector switch to ON or REMOTE
position.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a five minute
time period. Gas may accumulate in firebox. Call a quali-
fied service technician.
Note: If the module is in LOCK-OUT mode, resetting the
circuit breaker to the appliance will also reset the module.
Note: For units installed in Australia, the residence's 220/240
vac wall outlet to which this appliance's power cord is
connected, must be wired to an in-line on/off switch. This is
required for servicing and/or resetting the control module in
the event of a control module LOCK-OUT.
SELECTOR
SWITCH
LP/NG GAS-TYPE
SELECTOR SWITCH
Heat & Glo • Cosmo-I30AU • 2243-900 Rev. W • 10/14
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the wall
switch or optional remote.
I. Before Lighting Fireplace
Before operating this fireplace for the first time, have a
qualified technician:
• Verify all shipping materials have been removed from
inside and/or underneath the firebox.
• Review proper placement of logs, ember material and/
or other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT oper-
ate fireplace with fixed glass assembly removed.
Determine if this fireplace has a standing pilot or an In-
telliFire Plus
ignition system. Ask your dealer or open
TM
control access panel, look at gas valve.
• A standing pilot ignition will have a red or black ignitor
button (refer to Figure 2.4).
• An IntelliFire Plus
ignition system will not have a button.
TM
RED OR BLACK IGNITOR BUTTON
Figure 2.4 Ignitor Button
11

Advertisement

Table of Contents
loading

Table of Contents