Note: The header can only be installed in an existing masonry
chase or equivalent non-combustible enclosure. Clearances
around and above pipe must be adhered to.
SLP-TRAP
NOTE: Any 3 in. (76 mm) section
of flex pipe must be enclosed to
existing fireplace flue in double
l i n e d f l u e t o c o m p l y w i t h
AS2918-2001 and the building
code of Australia.
Seal connection points for duct-
ing.
NOTE: Tape all SLP pipe connec-
tions with aluminum foil tape rated
to a minimum of 300° F (149° C).
Figure 8.13 Optional SLP venting configuration - Horizontal Termination
11-7/8 in.
(600 mm)
MAXIMUM
10 ft. (3 m)
MINIMUM
FLEXIBLE FLUE
MIN. 35-7/16 in.
(900 mm)
Heat & Glo • Cosmo-I30AU • 2243-900 Rev. W • 10/14
Note: Adhere to AS5601 plumbers code for minimum clearances
for termination of balanced flue appliances.
SLP 90° BEND
Must adhere to pipe clearances.
Colinear to Coaxial Adapter
LINK ADAPTER
225 & 275 Ø
GALVANIZED FLUE
STARTER PLATE
31