Heat & Glo COSMO42-IFT Installation Manual

Heat & Glo COSMO42-IFT Installation Manual

Vented gas fireplace heater
Hide thumbs Also See for COSMO42-IFT:
Table of Contents

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo COSMO42-IFT

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 2: Table Of Contents

    C. Securing and Leveling the Appliance ....36 D. Non-Combustible Material Installation ....37  = Contains updated information. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2491-982 9/17 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 4: Product Specific And Important Safety Information

    Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 5: Non-Combustible Materials Specification

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 7: Getting Started

    Electric drill and bits: (1/4 in./Phillips #2) Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 8: Inspect Appliance And Components

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 9: Framing And Clearances

    Location Inches Millimeters 16-3/4 6-5/8 27-1/4 34-3/8 15-1/4 2-3/16 38-1/16 3-1/2 17-1/4 25-7/8 1041 38-1/2 9-13/16 17-3/4 10-5/8 25-3/4 7-3/4 Figure 3.1 Appliance Dimensions - COSMO32-IFT Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 10 1219 6-5/8 1092 32-3/8 39-1/16 2-3/16 15-1/4 33-11/16 17-1/4 3-1/2 25-7/8 47-1/16 1195 50-1/2 1283 9-13/16 17-3/4 10-5/8 37-3/4 7-3/4 Figure 3.2 Appliance Dimensions - COSMO42-IFT Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 11 14-1/8 33-1/8 6-7/8 9-13/16 19-7/8 26-7/8 COSMO32-IFT CFT-32 40-3/16 14-1/8 45-1/8 6-7/8 9-13/16 19-7/8 26-7/8 COSMO42-IFT CFT-42 1021 1146 Figure 3.3 Decorative Front Dimensions - CFT Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 12 14-7/8 34-3/16 6-5/16 9-3/8 20-3/4 27-1/8 COSMO32-IFT MAR-COSMO32 40-1/4 14-7/8 46-3/16 6-5/16 9-5/16 20-3/4 27-1/16 COSMO42-IFT MAR-COSMO42 1023 1172 Figure 3.4 Decorative Front Dimensions - MARTINI Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 13: Clearances To Combustibles

    15-1/16 17-1/4 COSMO32-IFT Millimeters 1134 1603 See Section 10.C for Alcove Installation. Inches 50-1/2 71-1/2 19-1/2 17-1/4 COSMO42-IFT Millimeters 1283 1245 1816 Figure 3.5 Appliance Locations Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 14 (Depth) (Width) 8-5/8 36-1/2 17-3/4 COSMO32-IFT 8-5/8 32-3/4 17-3/4 COSMO42-IFT 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 3.6 Clearances to Combustibles Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 15: Constructing The Appliance Chase

    • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 16: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 17: Chimney Diagram

    • Vinyl protection kits are suggested for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 18: Approved Pipe

    WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 19: Use Of Elbows

    Figure 4.5 Vertical and Horizontal Offset for SLP Elbows SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 SLP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.4 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 20: Measuring Standards

    • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.6 Measure to Outside Mounting Surface Figure 4.7 Measure to Top of Last Section of Pipe Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 21: Use Of Flex Vent (Slp-Flex Series 6-5/8 Inch)

    See Figure 4.9. FLEX-VENT 1 in. CLEARANCE 1/4 in. max. (6 mm) Figure 4.8 Flex Vent Pipe - Generic Fireplace Shown Figure 4.9 Vent Cap Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 22 When using SLP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow. Figure 4.10 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 23 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. INSTALLED HORIZONTALLY Figure 4.11 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 24 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. Figure 4.12 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 25 MAX. = 15 ft. (4.6 m) MAX. = 7 ft (2.1 m) glass breakage. INSTALLED HORIZONTALLY INSTALLED HORIZONTALLY Figure 4.13 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 26 Note: Use SLP Series components only. Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed. Figure 4.14 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 27 3. COSMO42-IFT Only: Reinstall shield by securing it with the two wing nuts and two screws previously re- moved in Step 1. EXHAUST RESTRICTOR INSTALLED SCREWS Figure 4.15 Installing Restrictor Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 28 H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. Note: Use SLP Series components only. Figure 4.16 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 29 H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. INSTALLED HORIZONTALLY Figure 4.17 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 30 Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.8. Figure 4.18 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 31 • Installer MUST install the 3 ft. stainless steel flex on ing with the DV-46DVA-GCL adapter and LINK-DV30B COSMO32-IFT. kit. This could result in poor flame appearance, sooting, pilot malfunction, or overheating. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 32 To minimize cold air drafts, seal with non-combustible insulation. DIRECT VENT FIREPLACE Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m HEARTH FLOOR Figure 4.21 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 33: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is 1 in. (25 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 34: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 35: Appliance Preparation

    IN POSITION KNOCKOUT LOCATIONS (RIGHT & LEFT SIDES) Figure 6.4 COSMO32-IFT - Shipping Support and Seal Cap Removed Figure 6.2 COSMO42-IFT - Top Heat Shield in Position Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 36: Installing Optional Heat Management Systems

    FACTORY-INSTALLED NON-COMBUSTIBLE BOARD DO NOT REMOVE NAILING TABS BOTH SIDES Figure 6.5 Proper Positioning, Leveling And Securing Of Appliance Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 37: Non-Combustible Material Installation

    OF THE PROVIDED 10 for more information. SCREWS INTO THESE PILOT HOLES NOTE: BOTH LEFT & RIGHT SIDES Figure 6.7 Installation of the Side Non-Combustible Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 38: Venting And Chimneys

    Use care when remov- ing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent could leak. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 39: Assemble Slip Sections

    “Assembling Pipe Sections.” NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 40: Secure The Vent Sections

    Figure 7.7 Rotate Seams for Disassembly connection point to appliance. 120º Figure 7.8 Align and Disassemble Vent Sections Figure 7.5 Securing Vertical Pipe Sections 120º Figure 7.6 Securing Horizontal Pipe Sections Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 41: Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.10. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 42: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Figure 7.12 Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 43 CAUTION! Risk of Burns! Local codes may require in- INTERIOR EXTERIOR stallation of a cap shield to prevent anything or anyone from touching the hot cap. Figure 7.13 Venting Through the Wall Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 44: Electrical Information

    GRN screw with BOTTOM PANEL SCREW LOCATIONS inside box GRN wire Figure 8.1 Remove Lower Access Panel Figure 8.4. Junction Box Wiring (Generic Model Shown) Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 45: Wiring Requirements

    Do not store batteries in the battery pack when the appliance is powered by the 6 volt transformer connected to permanent electrical service. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 46 Note: Wire assembly (2118 -170) is shipped in the manual bag assembly. Usage is optional. WHITE WIRE ASSEMBLY 2118-170 Figure 8.5 Intellifire™ Touch Wiring Diagram - Standard Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 47 WIRELESS CONTROL WALL SWITCH 6V DC LED-LINEAR BATTERY PACK Components shown in diagram. 2326-134 Figure 8.6 Intellifire™ Touch Wiring Diagram with Remote, Fan and LED Options Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 48 PVI-WH20 PVI-WH40 PVI-WH60 ORANGE PVI-WH80 PVI-WH100 GROUND TO FIREPLACE CHASSIS PVI-SLP-B OR PVLP-SLP GREEN PVLP-SLP PVI-SLP-B Figure 8.7 Intellifire™ Touch Wiring Diagram with Power Vent Diagram Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 49: Gas Information

    1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult Figure 9.1 Basepan Removal - COSMO42-IFT Shown local codes for compliance. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 50 Remove glass assembly and utilize an appropriate sized screwdriver. REMOVE BURNER SCREW Figure 9.2 Burner Removal Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 51: Gas Connection

    (1370 m)above sea level. Please consult provincial and/ or local authorities having jurisdiction for installations at elevations above 4500 feet (1370 m). Check with your local gas utility to determine proper orifice size. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 52: Finishing

    • Facing and/or finishing materials must not interfere with air flow through decorative fronts. • Facing and/or finishing materials must never overhang into the glass opening. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 53: Non-Combustible Board And Drywall Installation

    If a blemish begins to show over a screw head, sand the surface to remove the blemish and repaint. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 54 Do not drill or install screws which may penetrate the lower cover panel as this will restrict required access to the glass, battery-backup, and control module. See Figure 10.2. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 55: Mantel And Wall Projections

    TO TOP OF APPLIANCE OPENING APPLIANCE OPENING Figure 10.4 Clearances To Non-Combustible Mantels Or Other Non-Combustibles Above Appliance Figure 10.3 Clearances To Combustibles Mantels Or Other Combustibles Above Appliance Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 56 7 IN. MIN. WALL APPLIANCE OPENING UNLIMITED Figure 10.6 Combustible or Non-Combustible Mantel Leg or Wall Projections - Unlimited Wall Length (Acceptable on both sides of opening) Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 57: Decorative Front Finishing

    DECORATIVE FRONT (TOP EDGE) Finishing materials 1 inch maximum thick. Stop finishing material flush with opening. Figure 10.7 Overlap Fit Decorative Front (CFT and Martini Decorative Fronts) Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 58 Figure 10.9 Maximum Finish Material Thickness - CFT Decorative OUTER DECORATIVE Front FRONT TRIM INNER DECORATIVE FRONT ASSEMBLY TOP VANITY PANEL (NOT SHOWN) Figure 10.11 CFT Front Installation With Outer Decorative Front Trim Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 59 0 IN. (CFT) Figure 10.12 Clearances to Appliance Opening Without Outer Decorative Front Trim (BOTH SIDES) (BOTH SIDES) Figure 10.13 CFT Front Without Outer Decorative Front Trim Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 60: Appliance Setup

    C. Clean the Appliance glass refractory per instructions included with the kit. Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 61: Install Led Lights (Optional)

    WARNING! Risk of Explosion! Risk of Asphyxiation! Glass latches MUST be properly engaged. Inspect glass seal before installing decorative front. Gas could leak! 5. Reinstall decorative front. Figure 11.2 Media Placement Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 62: Install Decorative Front

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 63: Reference Materials

    1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.1 SLP Series Vent Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 64 12-5/8 IN. 10-5/8 IN. 59 mm 367 mm (321 mm) (270 mm) SLP-RDS SLP-WT-BK ROOF DECK INSULATION SHIELD Wall Thimble-Black Figure 12.2 SLP Series Vent Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 65 7-3/4 to 10-3/8 in. 343 mm 121 mm (197 to 264 mm) DVP-FBHT Horizontal Termination Cap SLK-SNKD (SL-2DVP Required) Snorkel Termination Cap Figure 12.3 SLP Series Vent Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 66 COAXIAL to COLINEAR VENTING LINK-DV30B 768-380A DV-46DVA-GCL Flex Liner Kit Stainless Steel Flex Pipe Coaxial/Colinear Appliance Connector (Required on COSMO32-IFT) Figure 12.5 Coaxial to Colinear Vent Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 67 (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Figure 12.6 PVI-SLP-B Vent Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 68 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.7 PVLP-SLP Vent Components Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...
  • Page 69: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2017 Heat & Glo • COSMO42-IFT, COSMO32-IFT Installation Manual • 2491-980 Rev. C • 11/17...