Figure 79. Unplug The Take-Up Motor; Logic Board Procedures; Logic Board Replacement - Ioline FlexJet Service Manual

Flexjet
Hide thumbs Also See for FlexJet:
Table of Contents

Advertisement

Logic Board Procedures

Logic board replacement

Tools Required:
n
Phillips head screwdriver
n
/
-in Allen wrench
5
32
1.
Unplug the take-up motor cable from the bottom of the ma-
chine. Unplug the power and serial cable. (Figure 79.)
2.
Remove the right side cover of the machine. (Figure 80.)
Take-up
motor
cable

Figure 79. Unplug the take-up motor.

3.
Remove the four Phillips screws that hold the logic board cover
on. (Figure 81.)
4.
Make sure you are grounded with a static grounding strap. For
now, leave the new logic board in its packaging. Remove the
logic board cover on the FlexJet. Carefully unplug the take-up
connector from the logic board before completelly removing
the cover. (Figure 82.)
Cover screws (rear)
Figure 81. Unscrew the PCB cover.
5.
Label the cables to make it easy to rematch during re-assembly.
Carefully unplug the connections from the board. Remove the
six silver phillips screws holding the board in the machine.
Figure 80. Remove the right cover.
Figure 82. Remove the logic board cover.
Chapter 4: Repair Procedures
83

Advertisement