PowerSeries - PC1616/PC1832/PC1864
[,][6] User Functions
Press [,][6] followed by the Master Code, then press the number corresponding to the following functions:
[1]
Program Time and Date:
twenty-four-hour system (e.g., 8:00 PM = 2000 hours).
[2]
Auto-arm/Auto-disarm Enable/Disable:
steady 2-second tone if it is now disabled.
[3]
Auto-arm Time/Day:
time (HH:MM). Program the time using the twenty-four-hour system (e.g., 8:00 PM = 2000 hours).
[4]
The panel will perform the following: activate the bell output, keypad buzzer and all keypad status lights for 2 seconds,
System Test:
test the backup battery and transmit a reporting code to the central station (if programmed).
[5]
Enable DLS: The panel will temporarily enable DLS for 1 or 6 hours depending on programming (see Sect [702] opt.[7]).
[6]
User Initiated DLS:
[7] -[8]
For Future Use
If using LCD keypads, scroll to the desired option then press [,].
Additional Alphanumeric Keypad Functions:
When scrolling through the list of available functions, the following additional functions are available:
Event Buffer:
Brightness Control:
Contrast Control:
Buzzer Control:
[,][7][x] Command Output (1-4)
Press [,][7][x]. If the Command Output Code Required option is enabled, enter a valid user code. The panel will activate any PGM output
assigned to the command output.
[,][8] Installer Programming
Press [,][8] followed by the Installer Code to enter Installer Programming. Refer to the 'How to Program' section for more information.
[,][9][User Code] No-Entry Arming
Press [,][9] followed by a valid user code. The system will arm in the Stay mode, and after the exit delay expires, it will remove entry delay.
All zones programmed as Delay will function like Instant zones. The system will flash the Armed light to indicate that the system is armed
with no entry delay.
[,][0] Quick Arm/Quick Exit
Quick Arm: When disarmed, press [,][0] to arm the system. The system will arm as if a valid user code was entered.
Quick Exit: When armed, press [,][0] to activate Quick Exit. The system will allow a single zone programmed as Delay to be violated a
single time during the following 2-minute time period without changing the status of the system.

2.5 Function Keys

Keypads have 5 programmable one-touch function buttons located in a column down the right side of the keypad. These buttons can also be
activated by pressing and holding numbers [1] through [5] respectively for 2 seconds. The default for these function buttons on the PK series
keypads are as follows:
[1] Stay Arm
[2] Away Arm
[3] Chime Enable/Disable
[4] Fire Reset – Command Output 2
[5] Quick Exit
Enter the time and date using the following format [HH:MM] [MM/DD/YY]. Program the time using the
The keypad will emit 3 rapid beeps if the Auto-arm/Auto-disarm feature is now enabled and a
Press the number corresponding to the day of the week (1=Sunday, 2=Monday etc.) followed by the auto- arm
The panel will attempt to call the DLS computer.
Used to view the 500-event panel log
Used to adjust the display backlighting level for optimal viewing
Used to adjust the display contrast level for optimal viewing
Used to adjust the keypad buzzer tone for optimal sound
8