DSC PowerSeries PC1616 Installation Manual page 49

V4.6 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
[380] First Communicator Options
Opt
Def
ON
 J
Communications Enabled
1
J
Restorals on Bell Time-out
2
J
Pulse Dialing
3
J
Switch to Pulse Dialing on 5th Attempt
4
J
3rd Telephone Number Enabled
5
J
Alternate Dial (1st & 3rd)
6
J
For Future Use
7
J
Delinquency Follows Zone Activity (Hours)
8
[381] Second Communicator Options
Opt
Def
ON
J
Open After Alarm Keypad Ringback Enabled
1
J
Open After Alarm Bell Ringback Enabled
2
J
SIA Sends Programmed Reporting Codes
3
J
Closing Confirmation Enabled
4
 J
Talk/Listen on Phone Lines 1/3
5
 J
Talk/Listen on Phone Line 2
6
J
Contact ID Uses Programmed Reporting Codes
7
J
ULC Communications Priority Enabled
8
[382] Third Communicator Options
Opt
Def
ON
J
For Future Use
1
J
Alarm Communications Enabled During Walk Test*
2
J
Communication Cancelled Message Enabled (ON for SIA CP-01)
3
J
Call Waiting Cancel Enabled**
4
J
T-Link Interface Enabled
5
J
AC Failure Transmission Delay is in Hours
6
J
Number of Dialing Attempt for Residential Dial is 1
7
J
For Future Use
8
*This option must remain OFF for SIA CP-01 installations.
** A Call Waiting Cancel on a non-Call Waiting line will prevent successful connection to the central station.
[383] Fourth Communicator Options
Opt
Def
ON
J
Account Code Follows Phone Number
1
J
For Future Use
2-8
[389] TL/GS Module Fault Check Timer
003
Default:
I_______I_______I_______I
Enter no. of checks X 3 seconds - valid entries 002 to 255
OFF
J
Communications Disabled
 J
Restorals Follow Zones
 J
DTMF Dialing
 J
DTMF Dial For All Attempts
 J
3rd Telephone Number Disabled
 J
Call 1st Number, Back up to 3rd
 J
 J
Delinquency Follows Arming (Days)
OFF
 J
Open After Alarm Keypad Ringback Disabled
 J
Open After Alarm Bell Ringback Disabled
 J
SIA Sends Automatic Reporting Codes
 J
Closing Confirmation Disabled
J
No Talk/Listen on Phone Lines 1/3
J
No Talk/Listen on Phone Line 2
 J
Contact ID Uses Automatic Reporting Codes
J
ULC Communications Priority Disabled/Standard Priority
Followed
OFF
J
J
Alarm Communications Disabled During Walk Test
J
Communication Cancelled Message Disabled
J
Call Waiting Cancel Disabled
J
T-Link Interface Disabled
J
AC Failure Transmission Delay is in Minutes
J
Residential Dial Follows Dialing Attempts Counter
J
OFF
J
Account Code Follows Partition
J
46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864

Table of Contents