DSC PowerSeries PC1616 Installation Manual page 17

V4.6 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
[013] First System Option Code
Option
Description
[1]
ON: zones require normally-closed loops. OFF: zones require End-Of-Line resistors, as determined by option [2].
[2]
ON: zones require double End-Of-Line resistors. OFF: zones require single End-Of-Line resistors.
[3]
ON: keypads will display all trouble conditions while armed. OFF: keypads will only display fire trouble when armed. This option
must be OFF if LCD5500 v2.x (or older) keypads are used on the system.
[4]
ON: only a trouble will be displayed. OFF: keypads will display a trouble and a zone violation if a tamper or fault is detected.
[5]
ON: auto-arming schedules (Program Sections [181]-[188]) will be available to the user in the [,][6] menu.
OFF: auto-arming schedules will not be available to the user in the [,][6] menu.
[6]
ON: the Audible Exit Fault feature will be enabled. If a delay zone is not secured correctly and not force-armed at the end of the exit
delay, the system will go into entry delay and turn ON the bell output. The bell will also sound if the delay zone is opened within 10
seconds of the exit delay timeout.
OFF: the keypad will sound the entry delay through the keypad as per usual.
[7]
ON: the system will NOT log additional alarms for a zone that has reached the swinger shutdown threshold.
OFF: all zone alarms will be logged.
[8]
ON: Temporal Three Fire Signal is used to sound fire alarms (½ second ON, ½ second OFF, ½ second ON, ½ second OFF ½ second
ON, 1 ½ seconds OFF).
OFF: the system will pulse the bell output (½ second ON, ½ second OFF).
[014] Second System Option Code
Option
Description
[1]
ON: the system squawks the bell output once when a partition is armed, twice when disarmed.
OFF: the bell output does not activate. Refer to section [017] option 8.
[2]
ON: the system squawks the bell output every 10 seconds during the auto-arm pre-alert.
OFF: the bell output does not activate.
[3]
ON: the system will squawk the bell output once every second during Exit Delay, 3 squawks per second for the last 10s.
OFF: the bell output will not activate.
[4]
ON: the system will squawk the bell output once every second during Entry Delay, 3 squawks per second for the last 10s.
OFF: the bell output will not activate.
[5]
ON: the system squawks the bell output once every 10 seconds when a trouble condition is present.
OFF: the bell output does not activate.
[6]
ON: the system will beep the keypads once every second, and 3 times a second over the last 10 seconds, during an exit delay when
the system is armed with a user code or armed in the Away mode.
OFF: the keypads will not beep.
[7]
ON: the exit delay will be terminated (reduced to 5 seconds) when a Delay 1 zone is violated and restored after the system is armed.
OFF: the exit delay will count down as normal.
[8]
ON: the bell output will not timeout if a fire alarm occurs. The user must turn OFF the bell by entering a valid user code.
OFF: the bell output will timeout normally.
[015] Third System Option Code
Option
Description
[1]
ON: the keypad fire emergency key will be enabled. OFF: the keypad fire emergency key will be disabled.
[2]
ON: the keypad Panic emergency will be audible (bell output). OFF: the Panic emergency key will be silent.
[3]
ON: the Quick Exit feature will be enabled. OFF: the Quick Exit feature will be disabled.
[4]
ON: the Quick Arming [
If this feature is disabled, a valid user code must be entered after the Stay or Away function buttons are pressed.
[5]
ON: a valid user code must be entered after pressing [
[6]
ON: the Master Code (user code 40) can only be changed in Installer Programming.
OFF: the Master Code can be changed using the User Programming [
[7]
ON: the system supervises the telephone line and displays a trouble if disconnected.
OFF: the telephone line is not supervised.
[8]
ON: the system activates the bell output if a telephone line trouble is detected while the system is armed.
OFF: the system activates the keypad buzzer trouble tone.
,
][0] feature will be enabled. OFF: Quick Arming [
,
,
][0] feature will be disabled.
][1] to access the Bypass feature. OFF: user code is not required.
,
][5] command.
14