Section 8 Controller Troubleshooting - Kohler 4EOZ Service

Marine generator sets
Hide thumbs Also See for 4EOZ:
Table of Contents

Advertisement

K1 relay protects the
starter motor in the
event of an improper
engine start.
Engine battery
charger regulator.
The generator set
starts. The starting
cycle is completed.
Figure 8-1 Generator Set Starting Cycle
TP-6137 5/03

Section 8 Controller Troubleshooting

The electric fuel
pump (FP) refills the
fuel supply line.
The low oil pressure
switch (LOP) contacts
open.
Starter motor
K2 relay energizes
the fuel pump (FP)
and the fuel solenoid
(FS).
If the fuel solenoid
(FS) is energized, fuel
flows to the injection
pump.
The generator
set starts.
Section 8 Controller Troubleshooting
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3.5efoz

Table of Contents