Section 4 Intake And Exhaust System; Air Intake Silencer/Filter - Kohler 4EOZ Service

Marine generator sets
Hide thumbs Also See for 4EOZ:
Table of Contents

Advertisement

4.1 Air Intake Silencer/Filter

At the interval specified in the service schedule, clean
the air intake screen. Clean the silencer more frequently
if the generator set operates in dirty, dusty conditions.
1. Air Cleaner
Figure 4-1
Air Cleaner
1. Air cleaner screen
Figure 4-2
Air Cleaner Screen
TP-6137 5/03

Section 4 Intake and Exhaust System

Air Cleaner Service/Replacement
A dry-type air cleaner silences and filters the intake air.
The air intake silencer assembly connects to the intake
manifold via a flexible hose.
1. Remove the four screws to remove the air cleaner
cover.
1
2. Remove the air cleaner screen.
3. Tap the screen lightly against a flat surface to
dislodge loose surface dirt. Do not clean in any
liquid or use compressed air as these will damage
the screen.
4. Examine the screen and housing for damage and
wear. Replace the screen or housing if necessary.
5. Wipe the air cleaner cover and base with a clean
rag to remove any dirt. Ensure that dirt does not
enter the intake port.
TP-6134
6. Make sure that the sealing surfaces fit correctly,
and replace the four screws.
1
TP-6134
Section 4 Intake and Exhaust System
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3.5efoz

Table of Contents