Selector
No.
1
Not used.
Default reduction rate for failure of
2
automatic reduction during
recording
3
Backing up received data
4
Black ink empty sensor
Minimum short-OFF duration in
5
distinctive ringing
6
Not used.
|
8
NOTE: Selector 5 is applicable only to the U.S.A. versions.
Selector 2:
Default reduction rate for failure of automatic reduction during recording
l l
This selector sets the default reduction rate to be applied if the automatic reduction function fails
to record one-page data sent from the calling station in a single page of the current recording
paper.
If it is set to "0," the equipment records one-page data at full size (100%) without reduction; if it is
set to "1," the equipment records it at 70% size.
Selector 3:
Backing up received data
l l
This selector determines whether the equipment backs up received data into the DRAM (just as in
the backup operation to be performed if a paper-empty error, ink-empty error or cover-open error
occurs). Only the data received at the latest five transmission sequences may be backed up. To
print out the backed-up data, press the Help key while holding down the Shift key, or carry out
purging operation.
Selector 5
Minimum short-OFF duration in distinctive ringing
l l
The ringer pattern consists of short and long rings, e.g., short-short-long rings. This selector sets
the minimum OFF duration following a short ring in order to avoid missing ringer tones in
distinctive ringing.
If this selector is set to "1," when the short-OFF duration is a minimum of 90 ms long, then the
equipment will interpret the short-OFF as OFF.
WSW31
(Function setting 9)
Function
V - 40
Setting and Specifications
0: 100%
1: 70%
0: Yes
1: No
0: Yes
1: No
0: 130 ms
1: 90 ms