Parameter
Function name
No.
Frequency
b086
conversion
coefficient
STOP key
b087
selection
Free-run stop
b088
selection
Monitor display
b089
selection
b091
Stop selection
b092
Cooling fan control
Overvoltage LAD
b130
stop function
Overvoltage LAD
b131
stop function level
setting
Overvoltage
protection function
b133
selection during
deceleration
Overvoltage
protection level
b134
setting during
deceleration
Overcurrent
b140
suppression
function
Automatic carrier
b150
reduction
Ready function
b151
selection
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Monitor or data range
(Digital Operator)
0.1 to 99.9
00: Enabled
01: Disabled
00: 0 Hz start
01: Frequency pull-in restart
01: Output frequency monitor
02: Output current monitor
03: Rotation direction monitor
04: PID feedback value monitor
05: Multi-function input monitor
06: Multi-function output monitor
07: Frequency conversion monitor
00: Deceleration → Stop
01: Free-run stop
00: Always ON
01: ON during RUN
02: Depends on the fin temperature
00: Disabled
01: Enabled
200-V class: 330. to 395.
400-V class: 660. to 790.
00: Disabled
01: Enabled
200-V class: 330. to 395.
400-V class: 660. to 790.
00: Disabled
01: Enabled
00: Disabled
01: Enabled
00: Disabled
01: Enabled
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
1.0
Yes
00
No
00
No
01
Yes
00
No
01
No
00
No
380/
Yes
V
760
00
No
380/
No
V
760
01
No
00
No
00
No
App-12