Omron 3G3JX User Manual page 211

Sysdrive jx series compact simplified inverters
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

Item
Multi-function output
Frequency monitor
Relay output
AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment,
jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-
shape acceleration/deceleration, electronic thermal characteristics/level adjustment, retry function, simplified
torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function,
motor rotation speed UP/DWN, overcurrent suppression function
Ambient temperature
Ambient storage
temperature
Humidity
Vibration
Location
Applicable standard
Options
*1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current
does not exceed that of the Inverter.
*2. Output voltage decreases according to the level of the power supply voltage.
*3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest
deceleration (when it stops from 50 Hz), not a continuous regenerative torque. Also, the average deceleration
torque varies depending on the motor loss. The value is reduced in operation at over 50 Hz. Note that no
regenerative braking circuit is built into the Inverter. If you need a larger regenerative torque, use the
optionally available regenerative braking unit and resistor. The regenerative braking unit should be used only
for short-time regeneration.
*4. Protection method complies with JEM 1030.
*5. To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable
number of revolutions.
*6. For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004
(A204) by 2 Hz max.
RUN (signal during operation), FA1 (frequency arrival signal), FA2 (over set
frequency arrival signal), OL (overload warning signal), OD (PID excess deviation
signal), AL (alarm output), DC (analog input disconnection detection signal), FBV
(PID FB status output), NDc (network error), LOG (logical operation result), ODc (Do
not use.), LOC (light load detection signal)
Analog output (0 to 10 V DC, 1 mA max.),
Frequency/Current signals are selectable via the AM output terminal.
The relay (SPDT contact) outputs signals corresponding to the multi-function output.
-10°C to 50°C (Both the carrier frequency and output current need to be reduced at
over 40°C.)
-20°C to 65°C (short-time temperature during transport)
20% to 90% RH
2
5.9 m/s
(0.6G), 10 to 55 Hz (Complies with the test method specified in JIS C0040
(1999).)
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Complies with UL, cUL, CE standards. (Insulation distance)
Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.
7-1 Standard Specification List
Specifications
7
7-4