IBM 6400-D Generation II Series Setup Manual page 140

Line matrix printers
Table of Contents

Advertisement

Chapter
6
Fault Messages
Fault
Message
062 MACHINE CHECK
SEE USERS GUIDE
065 HAMMER FAN CHECK*
SEE USERS GUIDE
069 DATA CLEARED
080 POWER SUPPLY HOT
140
Operator
Explanation
Correctable?
Yes
Sensors cannot detect
current in fan circuit.
Yes
Sensors cannot detect
current in fan circuit.
N/A
Appears when data is
cleared out of printer
after Cancel key has
been pressed.
No
Circuits are
overheating on the
power supply board.
Solution
Power off the printer
and remove paper
guide assembly (for
instructions, refer to
your IBM 6400
Maintenance
Information Manual ).
Check that the fan
cable is connected.
Check for obstruction
of vents and fan airway;
remove any
obstructions. Check for
items beneath the
printer blocking cabinet
vents. Power on the
printer. If this message
reoccurs, contact IBM
service.
NOTE: This message
should not
appear on a
Pedestal model.
If this message
does appear,
contact IBM
service.
Power off the printer
and remove paper
guide assembly (for
instructions, refer to
your IBM 6400
Maintenance
Information Manual ).
Check that the fan
cable is connected.
Check for obstruction
of vents and fan airway;
remove any
obstructions. Check for
items beneath the
printer blocking cabinet
vents. Power on the
printer. If this message
reoccurs, contact IBM
service.
No action necessary.
Contact IBM service.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6400-d3p6400-d3c6400-d6p6400-d6c6400-d8p6400-d8c

Table of Contents