Wiring - Empire Comfort Systems BF28BMN-4 Installation Instructions Manual

Mantis power-vent high-efficiency fireplace
Table of Contents

Advertisement

WARNING
Potential risk of fire, electric shock, and personal
injury. Take precautions to reduce such risks.
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
INDICATOR
SWITCH
+ -
R. BRN. THERM (4)
L. BRN. THERM (3)
27297-5-0511

WIRING

Figure 52
JUNCTION
BLOCK
C
W2
W1
WHITE
BLUE
BLACK
RED
PURPLE
YELLOW
P2
WHITE
BLACK
T2
BLUE
RED
T1
WHITE
BLACK
P1
WHITE
Figure 53
This
appliance
is
[grounding] plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the ground-
ing prong from this plug. For an ungrounded receptacle, an
adapter, which has two prongs and a wire for grounding, can
be purchased.
Proper line voltage polarity must be maintained in order for the
control system to operate correctly. Verify the incoming neutral
line is connected to the white wire and the incoming "hot" line is
connected to the black wire. The heater will not operate prop-
erly unless the polarity and ground are correct.
Instructions for connecting controllers and thermostats can be
found on page 32.
WHITE
WHITE
BLACK
R
TO
TRANSFORMER
BLUE
14 WAY RIBBON TO
CONTROL MODULE
equipped
with
a
three-prong
RECEIVER
OR
T-STAT
OPTIONAL
CONTROL
WIRING
Page 27

Advertisement

Table of Contents
loading