The Mantis should be inspected and serviced annually by a
qualified service person. This will ensure that the appliance is
operating safely and efficiently. Should you suspect any
abnormal operation, contact a service person that has been
trained to service this product.
Cleaning the Glass Door
After the initial paint curing, a slight film may form on the
glass. It is recommended to clean the glass with gas fire-
place glass cleaner.
The glass will need to be cleaned periodically during the
year. Use care when removing and cleaning the glass. In
the event the glass needs replaced, contact a qualified ser-
vice person. Only glass approved by Empire Comfort Sys-
tems Inc. may be used, any substitute glasses will void the
warranty.
CAUTION
Do not attempt to clean the glass when it is hot. Do
not strike or hit the glass.
WARNING
Do not operate this appliance without the glass door
in place. Do not operate if the glass front is broken or
damaged. Do not use the glass door if the gasket is
missing or is damaged.
CAUTION
Be certain the glass is cool before handling.
BAY WINDOW MANTIS MODELS
Removing the Glass Door
1. Remove the top of the cabinet.
2. Open the panels on the left and right sides. The panels
pivot in place.
3. Release the two door latches on both the left and right
sides of the firebox.
4. Carefully grab the glass frame and pull towards you. Do
not damage or remove the gasket from the door.
FIREPLACE MANTIS MODELS
Removing the Glass Door
1. Remove the lower louvered panel by lifting up then pull-
ing out.
2. Release the two hinge clips on underside of firebox.
3. Angle the bottom of glass assembly approximately
60 degrees out from firebox. Gently pull glass assembly
away from firebox. Do not damage or remove the gas-
ket from the door.
27297-5-0511
MAINTENANCE & SERVICE
Resetting the Heater
To reset the heater, first turn both burner switches to the OFF
position. Verify the red button next to the burners is not
illuminated. If a Remote Control is fitted, turn the remote to
the "OFF" position. Turn the power off at the power source for
5 minutes.
Turn the power back on, and verify the L.E.D. lights on the
Control Panel Circuit Plate are illuminated. The burners
should ignite in approximately 60 seconds. The circulating
blower will start in 3 to 5 minutes. The blower may continue
to operate after the burners are turned off.
WARNING
Potential risk of fire, electric shock, and personal in-
jury. Take precautions to reduce such risks
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after ser-
vicing.
If equipped, the Mantis can also be reset by switching the
main power switch to the "OFF" position for 5 minutes. See
Figure 62.