BAY WINDOW MANTIS CLEARANCE TO COMBUSTIBLES
ACCESS
PANEL
B
Figure 19
A
Rear Wall to Heater
B
Side Wall to Heater
C
Corner Installation
Coaxial Venting Installation Shown
Single Flue requires surround for combustion air.
Figure 21
Note: The Mantis Power-Vent High-Efficiency Fireplace has been tested and approved for zero clearance to combustible
materials. It is recommended that clearances as listed above should be maintained to allow for removal of the
product for servicing.
Page 18
A
B
Freestanding Clearances
2" (1-1/4" for coaxial venting)
0" (4" recommended for door clearance)
0"
C
Figure 20
CEILING
8"
6"
COMBUSTIBLE TRIM AND MANTELS
40"
4"
24"
18"
12"
Mantel and Ceiling Clearances
Figure 22
C
ALLOWED IN SHADED AREA
27297-5-0511