WIRING INSTRUCTIONS FOR INSTALLING A DUAL SWITCH / RECEPTACLE

In order to install both the optional Blower and Accent Light acces-
sories, it will be necessary to install the junction box so that the
Duplex Receptacle wiring is split. This will allow each side of the
receptacle to operate independently off separate wall switches.
See diagram below.
ACCENT LIGHT
WALL SWITCH
BLACK
TO 120V
WHITE
CIRCUIT
BREAKER
GROUND
1.
To wire Junction Box Receptacle, remove the tab on the side
of the receptacle (hot side) to split receptacle. This will be
required to separate blower and Accent Light circuits.
2.
Power for switched and live sides of Duplex Receptacle must
come from the same power source. (One circuit breaker on
main panel must switch all power off.)
3.
From the wall box to the fireplace a 3-wire conductor with
An Accent Light Kit model LK2 is available for installation in
the top of the firebox. Providing the junction box has been pre-
wired with separate circuits as described in the "Wiring for a dual
switch/receptacle" section, the Accent Light kit may be installed at
any time on louvered models, or on flush panel models prior to the
upper panels being covered with finishing materials.
39812-2-0620
#1
DOUBLE SWITCH BOX
(INSTALLER PROVIDED)
DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE

LK2 ACCENT LIGHT ACCESSORY

NOTE: To operate the FBB5 Blower accessory with a variable
speed control, the SCV1 Variable Speed Control Kit should be in-
stalled to control the power to one side of the duplex receptacle.
#2
BLOWER
WALL SWITCH
RED
BLACK
WHITE
GROUND
4-WIRE, GROUNDED
CONDUCTOR
(BY OTHERS)
ground is recommended, however (2) two-wire conductors
with grounds may be used in place of a 3-wire conductor with
a ground if the black wires from the Accent Light and blower
accessories are identified.
4.
Two wall switches may be used to activate the two receptacle
plugs independently.
Follow the instructions provided with the LK2 Accent Light kit for
proper installation in the fireplace/firebox.
REMOVE TAB ON HOT SIDE
OF DUPLEX RECEPTACLE
TO SPLIT LUGS
FIREPLACE
CONTROL
COMPARTMENT
PLUG
FOR
CONTROLS
PLUG
FOR
BLOWER
Page 11