FIREPLACE MANTIS LOG SET INSTALLATION INSTRUCTIONS

Log Installation
Positioning of the logs is critical to the safe and clean opera-
tion of this heater. If the logs are not placed in the proper
position, the appliance can soot, and create an unsafe op-
erating condition.
CAUTION
Do not handle these logs with your bare hands! Al-
ways wear gloves to prevent skin irritation. After han-
dling the logs, wash your hands gently with soap and
water.
Log Placement
1. Place the Rear Log (A) onto the rear log support. The
notch in the Rear Log fits over the rear igniter. See Fig-
ure 50.
2. Place Left Log (B) on the left rear log support shelf. The
charred portion of the log must face inward. See Figure
48.
3. Locate the Middle Log (D) on front log support between
the front and back burners.
Log Placement
Figure 48
G
Log Placement
Figure 49
Page 26
A
B
H
E
4. Place the Front Right Log (F) on the right side of firebox
bottom. The notch in the bottom of Front Right Log fits
over the front flame sensor. See Figure 51.
5. Place the Front Left Log (E) on left side of the firebox
bottom. The notch in bottom of Front Left Log fits over
front Igniter. See Figure 51.
6. Place the Right Log (C) on the right rear log support shelf.
The top of log rests on Rear Log (A) and bottom of log rests
on Firebox bottom. The charred portion of log must face
inward. See Figure 49.
7. Place the Left Top Long Log (G) on the pin on Left Log
(B). The upper left leg of Left Top Log will rest on Rear
Log (A). The upper right leg of Left Top Log will rest on
Middle Log (D).
8. Place the Right Top Long Log (H) on the pin on the
Right Log (C). The bottom left leg of Right Top Log (H)
will rest in the indentation on the right side of the Middle
Log (D). The bottom right leg of the Right Top Log (H)
will rest in the indentation in the Front Right Log (F).
9. Verify that the logs are not in contact with the flame sen-
sor. Interference with the flame sensor will effect the
operation.
D
F
B
Left Log
G
Left Top Log
Front Left Log
LEFT REAR
LOG SUPPORT
SHELF
C
FRONT HOT SURFACE IGNITOR
A
Middle Log
Rear Log
Front Right Log
E
Log Assembly
Figure 50
REAR HOT SURFACE IGNITOR
REAR FLAME SENSOR
REAR LOG SUPPORT
FRONT LOG SUPPORT
FIREBOX BOTTOM
FRONT BURNER
FRONT FLAME SENSOR
Firebox Layout
Figure 51
D
C
Right Log
H
Right Top Log
F
REAR BURNER
RIGHT REAR
LOG SUPPORT
SHELF
27297-5-0511

Advertisement

Table of Contents
loading

Table of Contents