Optional Controls - Empire Comfort Systems BF28BMN-4 Installation Instructions Manual

Mantis power-vent high-efficiency fireplace
Table of Contents

Advertisement

To use this feature, both burner switches need to be in the "ON"
position, and the red button must be pressed so it is illuminated.
This will ignite the front burner. The front burner will remain on
when the red button is illuminated, and the back burner will cycle
with the thermostat. The red button acts only as an override for the
front burner.
To Deactivate
Press the red button so it is not illuminated, then the heater will
return to normal operation.
TEMPERATURE CONTROLS
FRBTP
Battery Operated Remote w/ Programmable Ther-
mostat
FRBTC
Battery Operated Remote w/ Thermostat
TRW
Battery Operated Wireless Remote Wall Thermostat
TMV2
Thermostat, 2 Stage
T24V
Thermostat, 24 Volt
TDV1
Wall Thermostat, 24 Volt (Fireplace Mantis Only)
Installation Instructions for FRBTP, FRBTC, and TRW
CAUTION
Before connecting any controller, disconnect power
to the appliance.
Remote Controls FRBTP, FRBTC and TRW are all battery oper-
ated devices. Begin the installation by unplugging the unit and re-
moving the front louver panel or turn off main power switch.
Remove the wire nut from the black and white wire from junction
block.
The black or white wire can be inserted in either remote control
receiver connection hole, or connected to the T24V thermostat
screws. There is no polarity at this connection. See Figure 59.
REMOTE
BLACK
CONTROL
WHITE
RECEIVER OR
T24V THERMOSTAT
WHITE
JUNCTION
BLOCK
Replace the front louver panel and plug the unit into the outlet to
restore power. Turn both burner switches to the ON position. Burn-
er switches must remain in the ON position for the remote to func-
tion. Adjust the remote from the instructions provided with the re-
mote control. Set T24V thermostat to desired temperature.
Note: If the heater will not be used for long periods of time,
turn the burner switches to the "OFF" position and turn the
power off at the power source.
Page 32

OPTIONAL CONTROLS

C
W2
W1 R
TO
BLUE
TRANSFORMER
RED
TO "T1" (FRONT BURNER)
TO "T2" (REAR BURNER)
BLACK
WHITE
TO "T1"
BLUE
TO "T2"
Figure 59
Installation Instruction for TMV2 - Two Stage Thermostat
Model:
CAUTION: Before connecting any controller, disconnect
power to the appliance.
Begin the installation by removing the front louver panel.
Determine the mounting location of the thermostat. Using stan-
dard 18 AWG wire, run four (4) strands of wire to the back of the
appliance and to the junction block. Cut the wire to the correct
length. See Figure 60.
R
W1
TO
THERMOSTAT
W2
C
JUNCTION
C
BLOCK
Replace the front louver panel and plug unit into outlet, or restore
power. Turn both burner switches "ON." The burner switches must
remain in the ON position for thermostat to function. Set the ther-
mostat using the instructions provided with the thermostat.
Note: If the heater will not be used for long periods of time,
turn the burner switches to the "OFF" position and turn the
power off at the power source.
Mounting A Receiver Box
If a remote thermostat is used, the receiver must be located inside
the heater. The receiver can be mounted to the top of the blower
housing and secured with hook and loop tape. See Figure 61.
RECEIVER PLACEMENT
WHITE,
WHITE/
BLACK
REMOTE WIRE HARNESS
(TO BE REMOVED)
W2
W1 R
TO
TRANSFORMER
BLUE
RED
TO "T1" (FRONT BURNER)
TO "T2" (REAR BURNER)
BLACK
WHITE
TO "T1"
TO "T2"
BLUE
Figure 60
Figure 61
27297-5-0511

Advertisement

Table of Contents
loading

Table of Contents