The Colinear Transition Kit (Part number PVCT) is available
and can be used to secure the flue and inlet pipes from the
Mantis. When venting vertically, the exhaust pipe termina-
tion must be a minimum of 3 inches above the air inlet.
OPTIONAL
TERMINATION CAP
PVC CEMENT
PVC CEMENT
TRANSITION PLATE
Figure 12
Installation of the Colinear Transition Plate
1. Attach the plate to chimney chase, flat roof, or outside
wall with four (4) screws. Use outdoor sealant to seal
the transition plate to the surface.
2. Both inlet air pipe and flue exhaust pipe must be
12 inches from the roof line, and it is recommended to
be 12 inches above the maximum snow line. Also refer
to local codes. See Figures 12 and 13.
The Vent Adaptor Kits provide a transition from the appli-
ance to the flue and inlet pipes. Colinear Adaptor (part num-
ber PVCA) provides a transition for the inlet air. When using
Figure 14
27297-5-0511

COLINEAR TRANSITION VENT KIT

AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
3" MIN.
REQUIRED HEIGHT IS 12" MINIMUM.
IT IS RECOMMENDED TO BE 12" ABOVE
THE MAXIMUM EXPECTED SNOW LEVEL.
OUTDOOR SEALER REQUIRED

VENT ADAPTOR KITS

FLUE ADAPTOR
PLASTIC GASKET
THREADED CONNECTOR
INSTALL FOAM GASKET
The flue can be terminated with a PTrap or two 90° elbows.
The Vertical Termination Cap (Part number PVVTC) can
also be used to terminate the flue pipe when using the Co-
linear Transition Kit.
PVC CEMENT
PVC CEMENT
TRANSITION PLATE
Figure 13
3. Attach the flue and inlet air pipes to the transition plate.
Use the appropriate primer and cement to permanently
bond the joints and the pipes to the transition plate.
the flue adapter, use the appropriate primer and cement to
permanently bond the joints and the pipes. The inlet air pipe
does not need to be cemented.
Figure 15
EXHAUST
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
3" MIN.
REQUIRED HEIGHT IS 12" MINIMUM.
IT IS RECOMMENDED TO BE 12" ABOVE
THE MAXIMUM EXPECTED SNOW LEVEL.
OUTDOOR SEALER REQUIRED