Dvvk-4Re Vent Kit Installation Instructions - Empire Comfort Systems DVD32FP33N-4 Installation Instructions Manual

Direct-vent zero clearance gas fireplace
Table of Contents

Advertisement

DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS

CAUTION: Sharp edges, use protective gloves when installing.
Tools Needed for Installation:
Sheet metal snips
5/16" nut driver
Phillips head screwdriver - #2
High temperature sealant or furnace cement rated for continuous
use at 1,000ºF minimum
Measuring tape
PARTS VERIFICATION
See parts list on page 35 to verify components included in this vent
kit prior to installation.
NOTICE: If installing onto wood, lap, or vinyl siding, the vinyl siding
kit should be used (sold separately, part number DV-822).
The vinyl siding vent kit, DV-822, is available from Empire Comfort
Systems, Inc. The depth is 3" (76 mm), which enables the vent
cap to be extended away from vinyl siding or projections. The wall
depth plus the additional 3" (76 mm) depth of the vinyl siding vent
cap extension should not exceed a total depth of 13 3/4" (349 mm).
If wall depth exceeds 13 3/4" (349 mm), extend system using
6 5/8" (168 mm) x 4" (102 mm) rigid venting. See Fireplace Instruc-
tions for approved lengths. See Figure 51.
Installing Wall Thimble/Firestop Assembly
1. Fix fireplace to permanent location. If using rigid venting system,
install up to the location where it will exit the building.
2. Cut hole in wall for wall thimble/firestop assembly (Figure 50)
into your combustible wall. Note: On brick or block exterior wall
a 7" (178 mm) diameter hole needs to be cut.
Measure the total wall thickness to determine whether or not the
extension thimble is to be used. If the combustible wall depth
is over 5 3/8" (137 mm), then the extension thimble should be
used. See Figure 50.
3. Install the wall thimble assembly through the framed opening so
the firestop plate is on the interior wall. See Figure 50. Telescope
section should extend all the way through the exterior wall. At-
tach with four 10 x 1" screws.
4. When placing the vent cap on an exterior wall covered with
combustibles such as wood, lap, or vinyl siding, install the vinyl
siding kit to the exterior wall sheathing.
43115-2-0821
Cutting Vent Tubes
This is the most important part of the installation. With
the fireplace (and the rigid venting system if used) fixed to its
permanent location, the 6 5/8" (168 mm) diameter air inlet tube
and the 4" (102 mm) diameter flue outlet tube are to be marked
and cut using the following procedure.
5. Attach the inlet tube to the outside mounting plate. Align
tinnerman clips on the tabs of the air inlet tube to the holes on
outside mounting plate, and fix with two #10 x 1/2" screws.
6. With the vinyl siding kit installed to wall (if necessary), insert
the 6 5/8" (168 mm) diameter tube with outside mounting plate
attached through hole in wall. Connect to collar on fireplace or
rigid vent system. Measure between wall or vent cap extension
and outside mounting plate. See Figures 52 and 53.
Figure 50
Figure 51
Page 33