Clearances To Combustibles; Insert Leveling - Superior DRI3030TENC Installation And Operation Manual

Direct-vent fireplace insert
Hide thumbs Also See for DRI3030TENC:
Table of Contents

Advertisement

CLEARANCES TO COMBUSTIBLES

Minimum Clearances to Combustibles
Minimum clearances include any projections such as shelves, window
sills, mantels, spacers/standoffs or surfaces to combustible construction
etc. above the appliance. Paint or lacquer used to finish the mantel
must be heat resistant in order to avoid discoloration.
The letters in Figure 5 (A through E) show minimum clearances required
from the appliance to combustibles and the minimum projection of the
hearth extension.

Insert Leveling

At each front and rear corner of the insert is an adjustable leg provided
to level the insert should the hearth of the fireplace be uneven. To adjust
the legs, loosen the two 5/32" allen head screws, move the leg to the
desired height and then tighten the screws. Repeat these steps for each
adjusting leg.
Facing and Mantel Clearances
See Figure 4
MINIMUM FIREPLACE SIZES REQUIRED
Front Opening Width ....................................................... 31.50" (800mm)
Height ................................................................................. 19.50" (495mm)
Rear Width ........................................................................ 18.00" (457mm)
Depth ................................................................................. 16.00" (406mm)
MINIMUM CLEARANCES TO COMBUSTIBLES
A = Top Facing to Bottom of Appliance ..................... 31.5" (800mm)
B = Side Facing or Side Wall to Center of Glass ...... 25.5" (648mm)
C = 10.5" (267mm) Mantel to Bottom of Appliance . 39" (991mm)
HEARTH PROTECTION
D = Vertical Distance from base of appliance
to Hearth Extension ..........................................
E = Minimum Horizontal Distance
from Front of Appliance ......................................
Figure 5 - Clearances
10
....................
DRI3030TENC
0"
2"
(0mm)
(51mm) (102mm)
13"
10"
(330mm) (254mm) (0mm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
3"/76mm
3"/76mm
1-1/2"
38mm
33-1/2"
851mm
31-1/2"
36-1/2"
800mm
927mm
Figure 4
MINIMUM CLEARANCES
MANTEL
MANTEL
FACING
TRIM
A
Left
Side
4"
E
0"
NOTE: Hearth protection to be min.
3/8" (10mm) thick non-combustible
or equivalent, with a k factor of .84.
3"/76mm
DRI3030TENC
Facing and Mantel
Side View
39"
991mm
Front View
B
C
Right
C L
Side
D
Hearth Protection