CLEARANCES TO COMBUSTIBLES

IMPORTANT: If unit is converted to a DRI3030TEN-33 or
DRI2530TEN-33 from a DRI3030TEN-40 or DRI2530TEN-40,
the clearances to combustibles can be reduced as shown on
this page.
WARNING: If these units are ever converted back to a
DRI3030TEN-40 or DRI2530TEN-40, ensure that the clearances
are correct for these models.
Minimum Clearances to Combustibles
Minimum clearances include any projections such as shelves, window
sills, mantels, spacers/standoffs or surfaces to combustible construction
etc. above the appliance. Paint or lacquer used to finish the mantel
must be heat resistant in order to avoid discoloration.
The letters in Figure 5 (A through E) show minimum clearances required
from the appliance to combustibles and the minimum projection of the
hearth extension.

Insert Leveling

At each front and rear corner of the insert is an adjustable leg provided
to level the insert should the hearth of the fireplace be uneven. To adjust
the legs, loosen the two 5/32" allen head screws, move the leg to the
desired height and then tighten the screws. Repeat these steps for each
adjusting leg.
Facing and Mantel Clearances
Please note that the DRI3030TEN-33 and DRI2530TEN-33 mantel clear-
ances are 4" less than the DRI3030TEN-40 and DRI2530TEN-40 mantel
clearances as shown in Figure 4A - DRI3030TEN-40 and DRI2530TEN-40
and Figure 4B - DRI3030TEN-33 DRI2530TEN-33.
MINIMUM CLEARANCES TO COMBUSTIBLES
A = Top Facing to Bottom of Appliance ..................... 35-1/2" (902mm)
B = Side Facing or Side Wall to Center of Glass ...... 25-1/2" (648mm)
C = 10-1/2" (267mm) Mantel to Bottom of Appliance 43" (1092mm)
HEARTH PROTECTION
D = Vertical Distance from base of appliance
to Hearth Extension .......................................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm)
E = Minimum Horizontal Distance
from Front of Appliance .................................. (356mm) (254mm) (0mm) (330mm) (254mm) (0mm)
Figure 5 - Clearances
14
Figure 4A
Figure 4B
DRI3030TEN-40
DRI3030TEN-33
DRI2530TEN-40
DRI2530TEN-33
31-1/2" (800mm)
25-1/2" (648mm)
39" (991mm)
0"
2"
4"
0"
14"
10"
0"
13"
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
3"/76mm
3"/76mm
3"/76mm
1-1/2"
38mm
37-1/2"
39-1/2"
43"
33-1/2"
953mm
1003mm
1092mm
851mm
35-1/2"
40-1/2"
36-1/2"
31-1/2"
902mm
1029mm
927mm
800mm
3"/76mm
3"/76mm
3"/76mm
1-1/2"
38mm
39"
39-1/2"
33-1/2"
1003mm
991mm
851mm
31-1/2"
36-1/2"
800mm
927mm
MINIMUM CLEARANCES
MANTEL
MANTEL
FACING
TRIM
A
2"
4"
E
Hearth Protection
10"
0"
NOTE: Hearth protection to be min.
3/8" (10mm) thick non-combustible
or equivalent, with a k factor of .84.
DRI3030TEN-40
DRI2530TEN-40
Facing and Mantel
Side View
DRI3030TEN-33
DRI2530TEN-33
Facing and Mantel
Side View
B
C
C L
D